Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
60.0 ekW
Minimum Rating
27.0 ekW
Emissions/Fuel Strategy
EU Stage II & R96/EUIIIa
Voltage
110 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
Cat® C3.3
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1, 19.25:1
Aspiration
Turbocharged
Fuel System
Direct Injection
Governor Type
Mechanical
Length - Maximum
43.9in
Width - Maximum
38.2in
Height - Maximum
53.6in
Alternator System
LC Frame alternator
Anti-condensation heater
Permanent magnet excitation (PMG)
LC Frame alternator with coastal protection
R Frame auxilliary winding
Alternator
Alternator removal options
Circuit breakers
4 Pole Circuit breaker to 250A
Padlockable breaker device
Control Panels
GCCP 1.3
Control Panel Options
Overload shutdown via breaker
Volt free contacts
Earth leakage (2 wire only)
Speed adjust potentiometer
Voltage adjust potentiometer
Battery charger
Control panel heater
Earth fault (2 wire only)
Panel mounted audible alarm
Emergency stop with key
Cooling System
Coolant heater
Low coolant level shutdown
Low coolant temperature alarm
Certifications
European upgrade to STD set for "CE"
Global certification for CIS
Enclosures
CEE for sockets for enclosure
Socket blanking plate
Sound attenuated level 1 enclosure (GALV)
Sound attenuated level 2 enclosure CE
Rental pack (CAE only)
Fuel System
Skidbase for CALG enclosure sets
Low fuel level shutdown
High fuel level alarm
Compact skidbase for open sets
Low fuel level alarm
Bunded fuel tank
Open set narrow tankbase
Mounting Options
Silencer installation kit
Battery removal
Electronic governor
Residential silencer
External single point lift - enclosure
Special Packing Inspections
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
General
Stone guards/rad trans flange
Packing case - compact set
Packing case - canopied set
Air Inlet System
Air cleaner; light duty with disposable element
Control Panel
GCCP 1.3
Cooling System
Coolant drain line with valve
Caterpillar extended life coolant
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Exhaust System
Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied
Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
Circuit breaker, IEC, 3 pole, mounted in tower panel
IP23 Protection
Tower panel, IP22, bottom cable entry
12 Leads
Voltage regulator (single phase sensing)
Segregated low voltage (AC/DC) wiring panel
Governing System
Mechanical governing system - model dependant
Mechanical and electrical governing system - model dependant
Lube System
Lubricating oil
Oil drain line with valve
Mounting System
includes lifting provisions and termination points for coolant
Includes lifting provision and drag points
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Starting / Charging System
12V Battery with rack & cables
General
Engine and alternator pre-paint, Caterpillar yellow
ALL
Air Inlet System
Air cleaner; light duty with disposable element
Control Panel
GCCP 1.3
Cooling System
Coolant drain line with valve
Caterpillar extended life coolant
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Exhaust System
Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied
Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
Circuit breaker, IEC, 3 pole, mounted in tower panel
IP23 Protection
Tower panel, IP22, bottom cable entry
12 Leads
Voltage regulator (single phase sensing)
Segregated low voltage (AC/DC) wiring panel
Governing System
Mechanical governing system - model dependant
Mechanical and electrical governing system - model dependant
Lube System
Lubricating oil
Oil drain line with valve
Mounting System
includes lifting provisions and termination points for coolant
Includes lifting provision and drag points
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Starting / Charging System
12V Battery with rack & cables
General
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
LC Frame alternator
Anti-condensation heater
Permanent magnet excitation (PMG)
LC Frame alternator with coastal protection
R Frame auxilliary winding
Alternator
Alternator removal options
Circuit breakers
4 Pole Circuit breaker to 250A
Padlockable breaker device
Control Panels
GCCP 1.3
Control Panel Options
Overload shutdown via breaker
Volt free contacts
Earth leakage (2 wire only)
Speed adjust potentiometer
Voltage adjust potentiometer
Battery charger
Control panel heater
Earth fault (2 wire only)
Panel mounted audible alarm
Emergency stop with key
Cooling System
Coolant heater
Low coolant level shutdown
Low coolant temperature alarm
Certifications
European upgrade to STD set for "CE"
Global certification for CIS
Enclosures
CEE for sockets for enclosure
Socket blanking plate
Sound attenuated level 1 enclosure (GALV)
Sound attenuated level 2 enclosure CE
Rental pack (CAE only)
Fuel System
Skidbase for CALG enclosure sets
Low fuel level shutdown
High fuel level alarm
Compact skidbase for open sets
Low fuel level alarm
Bunded fuel tank
Open set narrow tankbase
Mounting Options
Silencer installation kit
Battery removal
Electronic governor
Residential silencer
External single point lift - enclosure
Special Packing Inspections
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
General
Stone guards/rad trans flange
Packing case - compact set
Packing case - canopied set