Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
500 ekW
Minimum Rating
320 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2, Tier 3, EU Stage IIIA
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby, Prime
Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.4in
Stroke
6.75in
Displacement
927.56in³
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Governor Type
Adem™A4
Length - Maximum
168.2in
Width - Maximum
81in
Height - Maximum
126.3in
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Certifications
EU Certificate of Conformance (CE)
Global certification for CIS
Circuit breakers
Shunt trip for IEC circuit breaker
Padlockable circuit breaker device
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Auxiliary contacts, circuit breaker
3 Pole (IEC-100% rated) Circuit breakers - Motorised
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power terminal strip
Generator
Oversize and premium generators
Anti-condensation heater
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Control Panels
GCCP 1.4
Volt free contacts
Local annunciator
Remote annunciator module
Local alarm horn
Oil temperature displays
Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
Starting/Charging
Jacket water heater
Charging alternator
Heavy duty starting system
Battery chargers
Oversize batteries
Cooling System
Stone guards
Radiator duct flange
Low coolant temperature alarm
Enclosures
Sound attenuated enclosures
High ambient sound attenuated enclosures
General
Sound attenuated, weather protective or high ambient weather protective enclosure
CSA Certification
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
EEC Declaration of Conformity
Integral & sub-base UL listed dual wall fuel tanks
Automatic transfer switches (ATS)
Single or dual wall sub-base fuel tanks
The following options are based on regional and product configuration:
EU Certificate of Conformance (CE)
Single or dual wall integral fuel tanks
Narrow, wide or skid base
UL 2200 package
Exhaust System
Engine mounted muffler
End in/end out mufflers - 10, 25 and 35 dBA attenuation
6 and 8 inch elbow kit
Manifold and turbocharger guards
Flexible exhaust fittings
6 and 8 inch flange GP
Fuel System
Manual fuel transfer pump
Dual wall fuel tank base
Fuel transfer system controls
Generator and Attachments
Space heaters
Permanent magnet excitation (PMG) generator
Ingress protection
LC frame generator
Oversize A Frame generator
LC frame CIP generator
CIP A Frame generator
Oversize LC frame generator
Lube System
Manual sump pump
Mounting System
Narrow skid base - replaces standard fuel tank base
Special Test / Reports
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Starting / Charging System
5 Amp single Battery charger
Battery disconnect switch
Jacket water heater
Air Inlet
Air cleaner
Air System
Turbocharger
Air cleaner - Non canister disposable paper filter
Aftercooler core
Control Panel
GCCP 1.3
GCCP 1.3 Genset Controller
Cooling
Package mounted radiator
Cooling System
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
Radiator and cooling fan with guard
Coolant drain line with valve
Exhaust
Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank/base supplied
Exhaust flange outlet
Fuel
Secondary fuel filters
Primary fuel filter with integral water separator
Fuel priming pump
Fuel System
Primary fuel filter w/integral water separator and secondary filter
Fuel priming pump
Engine fuel transfer pump
Flexible fuel lines
Fuel cooler
Generator
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
IP23 Protection
Power Termination
Busbar
Generator and Attachments
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
Segregated low voltage (AC/DC) wiring panel
Optional LC Frame generator - IP23 Protection
Power center, IP22
A Frame generator - IP21 Protection
Mounting
Rubber vibration isolators
Governing System
Cat electronic governor (ADEM A4).
Lube System
Oil cooler
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
ALL
Air Inlet
Air cleaner
Air System
Turbocharger
Air cleaner - Non canister disposable paper filter
Aftercooler core
Control Panel
GCCP 1.3
GCCP 1.3 Genset Controller
Cooling
Package mounted radiator
Cooling System
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
Radiator and cooling fan with guard
Coolant drain line with valve
Exhaust
Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank/base supplied
Exhaust flange outlet
Fuel
Secondary fuel filters
Primary fuel filter with integral water separator
Fuel priming pump
Fuel System
Primary fuel filter w/integral water separator and secondary filter
Fuel priming pump
Engine fuel transfer pump
Flexible fuel lines
Fuel cooler
Generator
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
IP23 Protection
Power Termination
Busbar
Generator and Attachments
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
Segregated low voltage (AC/DC) wiring panel
Optional LC Frame generator - IP23 Protection
Power center, IP22
A Frame generator - IP21 Protection
Mounting
Rubber vibration isolators
Governing System
Cat electronic governor (ADEM A4).
Lube System
Oil cooler
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Certifications
EU Certificate of Conformance (CE)
Global certification for CIS
Circuit breakers
Shunt trip for IEC circuit breaker
Padlockable circuit breaker device
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Auxiliary contacts, circuit breaker
3 Pole (IEC-100% rated) Circuit breakers - Motorised
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power terminal strip
Generator
Oversize and premium generators
Anti-condensation heater
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Control Panels
GCCP 1.4
Volt free contacts
Local annunciator
Remote annunciator module
Local alarm horn
Oil temperature displays
Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
Starting/Charging
Jacket water heater
Charging alternator
Heavy duty starting system
Battery chargers
Oversize batteries
Cooling System
Stone guards
Radiator duct flange
Low coolant temperature alarm
Enclosures
Sound attenuated enclosures
High ambient sound attenuated enclosures
General
Sound attenuated, weather protective or high ambient weather protective enclosure
CSA Certification
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
EEC Declaration of Conformity
Integral & sub-base UL listed dual wall fuel tanks
Automatic transfer switches (ATS)
Single or dual wall sub-base fuel tanks
The following options are based on regional and product configuration:
EU Certificate of Conformance (CE)
Single or dual wall integral fuel tanks
Narrow, wide or skid base
UL 2200 package
Exhaust System
Engine mounted muffler
End in/end out mufflers - 10, 25 and 35 dBA attenuation
6 and 8 inch elbow kit
Manifold and turbocharger guards
Flexible exhaust fittings
6 and 8 inch flange GP
Fuel System
Manual fuel transfer pump
Dual wall fuel tank base
Fuel transfer system controls
Generator and Attachments
Space heaters
Permanent magnet excitation (PMG) generator
Ingress protection
LC frame generator
Oversize A Frame generator
LC frame CIP generator
CIP A Frame generator
Oversize LC frame generator
Lube System
Manual sump pump
Mounting System
Narrow skid base - replaces standard fuel tank base
Special Test / Reports
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Starting / Charging System
5 Amp single Battery charger
Battery disconnect switch
Jacket water heater