Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
500 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.4in
Stroke
6.75in
Displacement
927.56in³
Compression Ratio
16.1:1
Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Governor Type
Adem™A4
Length - Maximum
168.2in
Width - Maximum
81in
Height - Maximum
82.4in
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Certifications
Global certification for CIS
EU Certificate of Conformance (CE)
Generator
Anti-condensation heater
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Oversize and premium generators
Circuit breakers
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power terminal strip
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Shunt trip for IEC circuit breaker
Padlockable circuit breaker device
Auxiliary contacts, circuit breaker
3 Pole (IEC-100% rated) Circuit breakers - Motorised
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power Termination
Circuit breakers, IEC compliant
Circuit breakers, UL listed
Control Panels
Remote annunciator module
Local alarm horn
Local annunciator
Oil temperature displays
GCCP 1.4
Volt free contacts
Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
Starting/Charging
Charging alternator
Battery chargers
Oversize batteries
Heavy duty starting system
Jacket water heater
Cooling System
Low coolant temperature alarm
Stone guards
Radiator duct flange
Enclosures
Sound attenuated enclosures
High ambient sound attenuated enclosures
Exhaust System
Engine mounted muffler
6 and 8 inch elbow kit
Manifold and turbocharger guards
End in/end out mufflers - 10, 25 and 35 dBA attenuation
6 and 8 inch flange GP
Flexible exhaust fittings
Fuel System
Fuel transfer system controls
Manual fuel transfer pump
Dual wall fuel tank base
General
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Sound attenuated, weather protective or high ambient weather protective enclosure
EU Certificate of Conformance (CE)
Single or dual wall integral fuel tanks
CSA Certification
EEC Declaration of Conformity
Narrow, wide or skid base
Integral & sub-base UL listed dual wall fuel tanks
Automatic transfer switches (ATS)
UL 2200 package
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
Generator and Attachments
Oversize LC frame generator
Oversize A Frame generator
CIP A Frame generator
LC frame generator
LC frame CIP generator
Ingress protection
Permanent magnet excitation (PMG) generator
Space heaters
Lube System
Manual sump pump
Mounting System
Narrow skid base - replaces standard fuel tank base
Special Test / Reports
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Starting / Charging System
5 Amp single Battery charger
Battery disconnect switch
Jacket water heater
Air System
Turbocharger
Air cleaner - Non canister disposable paper filter
Aftercooler core
Air Inlet
Air cleaner
Control Panel
GCCP 1.3
GCCP Genset Controller
Cooling
Package mounted radiator
Cooling System
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guard
Exhaust
Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank/base supplied
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Secondary fuel filters
Fuel priming pump
Fuel System
Engine fuel transfer pump
Flexible fuel lines
Fuel cooler
Fuel priming pump
Primary fuel filter w/integral water separator and secondary filter
Generator
IP23 Protection
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Matched to the performance and output characteristics of Cat engines
Power Termination
Busbar
Mounting
Rubber vibration isolators
Generator and Attachments
Segregated low voltage (AC/DC) wiring panel
Optional LC Frame generator - IP23 Protection
Power center, IP22
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
A Frame generator - IP21 Protection
Governing System
Cat electronic governor (ADEM A4).
Lube System
Oil drain valves
Oil cooler
Mounting System
Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
ALL
Air System
Turbocharger
Air cleaner - Non canister disposable paper filter
Aftercooler core
Air Inlet
Air cleaner
Control Panel
GCCP 1.3
GCCP Genset Controller
Cooling
Package mounted radiator
Cooling System
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guard
Exhaust
Base, formed steel with single wall integral 8-hour fuel tank
Standard open set fuel tank/base supplied
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Secondary fuel filters
Fuel priming pump
Fuel System
Engine fuel transfer pump
Flexible fuel lines
Fuel cooler
Fuel priming pump
Primary fuel filter w/integral water separator and secondary filter
Generator
IP23 Protection
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Matched to the performance and output characteristics of Cat engines
Power Termination
Busbar
Mounting
Rubber vibration isolators
Generator and Attachments
Segregated low voltage (AC/DC) wiring panel
Optional LC Frame generator - IP23 Protection
Power center, IP22
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
A Frame generator - IP21 Protection
Governing System
Cat electronic governor (ADEM A4).
Lube System
Oil drain valves
Oil cooler
Mounting System
Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Certifications
Global certification for CIS
EU Certificate of Conformance (CE)
Generator
Anti-condensation heater
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Oversize and premium generators
Circuit breakers
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power terminal strip
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Shunt trip for IEC circuit breaker
Padlockable circuit breaker device
Auxiliary contacts, circuit breaker
3 Pole (IEC-100% rated) Circuit breakers - Motorised
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Power Termination
Circuit breakers, IEC compliant
Circuit breakers, UL listed
Control Panels
Remote annunciator module
Local alarm horn
Local annunciator
Oil temperature displays
GCCP 1.4
Volt free contacts
Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
Starting/Charging
Charging alternator
Battery chargers
Oversize batteries
Heavy duty starting system
Jacket water heater
Cooling System
Low coolant temperature alarm
Stone guards
Radiator duct flange
Enclosures
Sound attenuated enclosures
High ambient sound attenuated enclosures
Exhaust System
Engine mounted muffler
6 and 8 inch elbow kit
Manifold and turbocharger guards
End in/end out mufflers - 10, 25 and 35 dBA attenuation
6 and 8 inch flange GP
Flexible exhaust fittings
Fuel System
Fuel transfer system controls
Manual fuel transfer pump
Dual wall fuel tank base
General
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Sound attenuated, weather protective or high ambient weather protective enclosure
EU Certificate of Conformance (CE)
Single or dual wall integral fuel tanks
CSA Certification
EEC Declaration of Conformity
Narrow, wide or skid base
Integral & sub-base UL listed dual wall fuel tanks
Automatic transfer switches (ATS)
UL 2200 package
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
Generator and Attachments
Oversize LC frame generator
Oversize A Frame generator
CIP A Frame generator
LC frame generator
LC frame CIP generator
Ingress protection
Permanent magnet excitation (PMG) generator
Space heaters
Lube System
Manual sump pump
Mounting System
Narrow skid base - replaces standard fuel tank base
Special Test / Reports
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Starting / Charging System
5 Amp single Battery charger
Battery disconnect switch
Jacket water heater