Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
60 ekW
Minimum Rating
36 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.13in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Governor Type
Adem™A4
Length - Maximum
75.8in
Width - Maximum
44.1in
Height - Maximum
53.6in
Certificates
IBC seismic and wind Certifications
Alternator System
R Frame auxilliary winding
Air Inlet System
Cartridge type air filter
Charging System
NFPA battery charger UL10A 120VAC
Circuit breakers
3-Pole 100% rated
Breakers (100% UL rated)
Second circuit breaker box
Power terminal strip
Control Panels
Discrete I/O module
Remote annunciator module
Remote E-stop button
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Ground fault relay
Audible alarm
Oil temperature gauge and sender
Volt free contacts genset run and common alarm
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Heating Elements
Coolant heater
Battery heater
Anti-condensation heater
Lube oil sump heater
Jacket water heater
Wiring for canopy space heater
Cooling System
Radiator transition flange
Enclosures
Panel viewing window
External emergency stop
Sound attenuated enclosure, Level 2
Weatherproof enclosure
Sound attenuated enclosure, Level 1
Fuel System
5 Gallon fill containment
Tank riser
209 and 394 gallon sub-base fuel tanks
Emergency vent pipe
5 Gallon spill containment
Mounting System
Seismic vibration isolators
Tests
Generator test report
PGS Test report @ 0.8 power factor
4 Hour factory test
PGS Test report @ 1.0 power factor
Exhaust System
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Generators
Permanent magnet excitation (PMG) generator
Certificates
IBC seismic and wind Certifications
Charging System
NFPA battery charger UL10A 120VAC
Air Inlet System
Air cleaner
Cartridge type air filter
Circuit breakers
Second circuit breaker box
3-Pole 100% rated
Power terminal strip
Breakers (100% UL rated)
Control Panel
1000028996
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
Cooling System
Coolant drain line with valve
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator stone guard
Generator
12 Leads
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Oil drain line with valve
Lubricating oil
Control Panels
WCA1 Low coolant temperature alarm
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
PAA1 Panel mounted audible alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
Oil temperature gauge and sender
PBC10NU NFPA battery charger
Ground fault relay
Discrete I/O module
Volt free contacts genset run and common alarm
Audible alarm
Remote E-stop button
Remote annunciator module
Low coolant temperature alarm
Protective devices:
Overload shutdown via breaker
Fuel level reading
Low coolant level shutdown
General
Engine and alternator pre-paint, Caterpillar yellow
Starting/Charging System
24V battery with rack and cables
Batteries
ALL
Certificates
IBC seismic and wind Certifications
Charging System
NFPA battery charger UL10A 120VAC
Air Inlet System
Air cleaner
Cartridge type air filter
Circuit breakers
Second circuit breaker box
3-Pole 100% rated
Power terminal strip
Breakers (100% UL rated)
Control Panel
1000028996
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
Cooling System
Coolant drain line with valve
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator stone guard
Generator
12 Leads
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Oil drain line with valve
Lubricating oil
Control Panels
WCA1 Low coolant temperature alarm
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
PAA1 Panel mounted audible alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
Oil temperature gauge and sender
PBC10NU NFPA battery charger
Ground fault relay
Discrete I/O module
Volt free contacts genset run and common alarm
Audible alarm
Remote E-stop button
Remote annunciator module
Low coolant temperature alarm
Protective devices:
Overload shutdown via breaker
Fuel level reading
Low coolant level shutdown
General
Engine and alternator pre-paint, Caterpillar yellow
Starting/Charging System
24V battery with rack and cables
Batteries
Optional Equipment
Certificates
IBC seismic and wind Certifications
Alternator System
R Frame auxilliary winding
Air Inlet System
Cartridge type air filter
Charging System
NFPA battery charger UL10A 120VAC
Circuit breakers
3-Pole 100% rated
Breakers (100% UL rated)
Second circuit breaker box
Power terminal strip
Control Panels
Discrete I/O module
Remote annunciator module
Remote E-stop button
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Ground fault relay
Audible alarm
Oil temperature gauge and sender
Volt free contacts genset run and common alarm
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Heating Elements
Coolant heater
Battery heater
Anti-condensation heater
Lube oil sump heater
Jacket water heater
Wiring for canopy space heater
Cooling System
Radiator transition flange
Enclosures
Panel viewing window
External emergency stop
Sound attenuated enclosure, Level 2
Weatherproof enclosure
Sound attenuated enclosure, Level 1
Fuel System
5 Gallon fill containment
Tank riser
209 and 394 gallon sub-base fuel tanks
Emergency vent pipe
5 Gallon spill containment
Mounting System
Seismic vibration isolators
Tests
Generator test report
PGS Test report @ 0.8 power factor
4 Hour factory test
PGS Test report @ 1.0 power factor
Exhaust System
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Generators
Permanent magnet excitation (PMG) generator