402

DE550S GC (60 Hz) Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

550 ekW

Minimum Rating

550 ekW

Emissions/Fuel Strategy

Non Regulated

Voltage

220 to 480 Volts

Frequency

60 Hz

Speed

1800 RPM

Duty Cycle

Standby

Engine Model

C15 In-line 6, 4-cycle diesel

Bore

5.4in

Stroke

6.8in

Displacement

928in³

Compression Ratio

16.1:1

Aspiration

Turbocharged Air-to-Air Aftercooled

Fuel System

EUI

Governor Type

Adem™A4

Length - Maximum

131in

Width - Maximum

60.6in

Height - Maximum

86.1in

Dry Weight - Genset (maximum)

8364lb

Control panel

Speed and Voltage adjust potentiometers

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Exhaust

Industrial, residential, critical mufflers

Enclosure

Cat GC enclosure

Generator

Oversize and premium generators

Anti-condensation heater

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Alternator

Space heater

AVR

Air inlet system

Single stage air filter

Dual element air filter

Starting/Charging

Heavy duty starting system

Battery chargers

Jacket water heater

Oversize batteries

Charging alternator

Certifications

EU Certificate of Conformance (CE)

EAC Certification

Extended service coverage

3, 4, 5 and 10 Years

General

The following options are based on regional and product configuration:

UL 2200 package

Integral & sub-base UL listed dual wall fuel tanks

Sound attenuated, weather protective or high ambient weather protective enclosure

EU Certificate of Conformance (CE)

EEC Declaration of Conformity

Single or dual wall integral fuel tanks

Single or dual wall sub-base fuel tanks

CSA Certification

Automatic transfer switches (ATS)

Narrow, wide or skid base

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

Enclosures

High ambient sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

6 and 8 inch elbow kit

Flexible exhaust fittings

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Engine mounted muffler

6 and 8 inch flange GP

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Fuel transfer system controls

Dual wall fuel tank base

Manual fuel transfer pump

Generator and Attachments

Ingress protection

CIP A Frame generator

Oversize A Frame generator

Permanent magnet excitation (PMG) generator

Space heaters

LC frame CIP generator

LC frame generator

Oversize LC frame generator

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

Battery disconnect switch

Jacket water heater

5 Amp single Battery charger

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Air Inlet

Air cleaner

Control Panels

GCCP 1.1

Governor

Mechanical governor

Alternator

A Frame standard alternator

Control Panel

EMCP 4 Genset controller

Cooling

Package mounted radiator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Exhaust

Exhaust flange outlet

Fuel

Fuel priming pump

Secondary fuel filters

Primary fuel filter with integral water separator

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Air inlet system

Air cleaner; light duty with disposable element

Lube system

Lubricating oil

Oil drain line with valve

Generator

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

IP23 Protection

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

Power Termination

Busbar

Generator and Attachments

Integrated voltage regulator (IVR)

Power center, IP22

Optional LC Frame generator - IP23 Protection

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Segregated low voltage (AC/DC) wiring panel

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil drain valves

Oil cooler

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

24 volt starting motor

Batteries

24 Volt battery with rack and cables

General

Engine and alternator pre paint, Caterpillar yellow

Paint - Caterpillar yellow except rails and radiators gloss black

Engine and alternator pre paint, Caterpillar yellow

ALL

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Air Inlet

Air cleaner

Control Panels

GCCP 1.1

Governor

Mechanical governor

Alternator

A Frame standard alternator

Control Panel

EMCP 4 Genset controller

Cooling

Package mounted radiator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Exhaust

Exhaust flange outlet

Fuel

Fuel priming pump

Secondary fuel filters

Primary fuel filter with integral water separator

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Air inlet system

Air cleaner; light duty with disposable element

Lube system

Lubricating oil

Oil drain line with valve

Generator

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

IP23 Protection

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

Power Termination

Busbar

Generator and Attachments

Integrated voltage regulator (IVR)

Power center, IP22

Optional LC Frame generator - IP23 Protection

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Segregated low voltage (AC/DC) wiring panel

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil drain valves

Oil cooler

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

24 volt starting motor

Batteries

24 Volt battery with rack and cables

General

Engine and alternator pre paint, Caterpillar yellow

Paint - Caterpillar yellow except rails and radiators gloss black

Engine and alternator pre paint, Caterpillar yellow

Optional Equipment

Control panel

Speed and Voltage adjust potentiometers

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Exhaust

Industrial, residential, critical mufflers

Enclosure

Cat GC enclosure

Generator

Oversize and premium generators

Anti-condensation heater

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Alternator

Space heater

AVR

Air inlet system

Single stage air filter

Dual element air filter

Starting/Charging

Heavy duty starting system

Battery chargers

Jacket water heater

Oversize batteries

Charging alternator

Certifications

EU Certificate of Conformance (CE)

EAC Certification

Extended service coverage

3, 4, 5 and 10 Years

General

The following options are based on regional and product configuration:

UL 2200 package

Integral & sub-base UL listed dual wall fuel tanks

Sound attenuated, weather protective or high ambient weather protective enclosure

EU Certificate of Conformance (CE)

EEC Declaration of Conformity

Single or dual wall integral fuel tanks

Single or dual wall sub-base fuel tanks

CSA Certification

Automatic transfer switches (ATS)

Narrow, wide or skid base

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

Enclosures

High ambient sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

6 and 8 inch elbow kit

Flexible exhaust fittings

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Engine mounted muffler

6 and 8 inch flange GP

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Fuel transfer system controls

Dual wall fuel tank base

Manual fuel transfer pump

Generator and Attachments

Ingress protection

CIP A Frame generator

Oversize A Frame generator

Permanent magnet excitation (PMG) generator

Space heaters

LC frame CIP generator

LC frame generator

Oversize LC frame generator

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

Battery disconnect switch

Jacket water heater

5 Amp single Battery charger

    Send an Enquiry