Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
600 ekW
Minimum Rating
600 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
480 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
Cat® C18 In-line 6, 4-cycle Diesel
Bore
5.7in
Stroke
7.2in
Displacement
1106in³
Compression Ratio
14.5:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
MEUI
Governor Type
ADEM™A4
Length - Maximum
196.1in
Width - Maximum
73.4in
Height - Minimum
79.1in
Height - Maximum
100.9in
Dry Weight - Genset (minimum)
8959.6lb
Dry Weight - Genset (maximum)
11647lb
Air Inlet System
Air cleaner (Non canister disposable)
Bases, Mounting & Fuel Tanks
Audio & visual fuel alarm (@90% fuel level)
Integral tank base, 24 hours, UL142
5 Gallon Spill Containment
Overfill prevention valve
Fuel tank pill pipe & lockable cap
Wide Base - Skid
Circuit breaker
400A LSI
Auxiliary contacts
400A LS/I
800A LSI
600A LSI
1200A LS/I
800A LS/I
600A LS/I
1200A LSI
Control System
20A GFCI (Ground Fault Circuit Interrupter)
Ground fault relay
16 -light NFPA 99/110 Annunciator
Volt free contacts
Twist release, Red button emergency stop
100A Load center
Product link remote monitoring hardware
Audible alarm Gp
Earth (Ground) fault relay
Volt free contact
Remote E-Stop button
Discrete I/O module
Annunciators box
Local annunciator
Exhaust System
8" Muffler - 25 dBA attenuation
Flexible exhaust connection
Manifold and turbocharger guards
Generator
Space heater
Permanent magnet excitation (PMG) generator
Starting System
Jacket water heater
Standard battery set: 1000 CCA, 90 amp/hr.
Battery charger (UL Certified)
Oversize battery set, 1400 CCA, 200 amp/hr
General
Extended Service Coverage
Generator test report
CSA Certification
UL2200 Certification
Tool set
Circuit breakers
Single LSI motorised circuit breaker
Single LSI motorised circuit breaker
Auxiliary contacts
Neutral bar (208V)
Enclosures
E-Stop
Sound attenuated Level 2 enclosure (White)
AC & DC Source lights
Sound attenuated enclosure
Cooling System
Coolant heater
Stone guards
Jacket water heater with pump
Base / Fuel Tank
Audio & visual fuel alarm
Fuel System
Integral 8 hour tank base
Starting and Charging
Oversize battery set
Standard battery set
5 Amp Battery charger
Battery disconnect switch
Certifications
CSA 22.2
UL2200 Listed
Seismic
Lube System
Manual sump pump
Air Inlet System
Turbocharger
Air cleaner - Non canister, disposable
Aftercooler core
Control Panel
GCCP 1.2
Cooling System
Radiator sight gauge
Thermostats and housing
Coolant drain valve
Jacket water pump, gear driven, centrifugal
Blower fan and fan drive with guards
Radiator, package mounted
Exhaust System
Exhaust manifold - dry
Fuel System
Fuel cooler
Primary fuel filter w/integral water separator and secondary filter, spin on
Integral tank base, 24 hours, UL142
Engine fuel transfer pump
Fuel priming pump
Generator Set
Complete system designed & built at ISO 9001:2000 certified facilities
Factory tested to design specifications at full load conditions
All protective devices and control functions simulated and checked
Generators and Generator Attachments
6 Leads
Voltage regulator (single phase sensing)
Easy access to AVR and terminals
Insulation system, Class H
Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
Terminal box, IP22 RHS facing, bottom cable entry
Standard winding protection for non-harsh environments with relative humidity ? 95%
IP23 Protection
Governing System
Cat electronic governor (ADEM A4)
Lube System
Oil filler and dipstick
Shallow oil pan
Oil filter, spin on
Oil cooler
Lubricating oil, CK-4 (10W-30)
Oil drain with valve
Fumes disposal to front of radiator
Mounting System
Includes lifting provisions and termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Protection
Safety shutoff - High water temperature
Safety shutoff - Overspeed
Safety shutoff - Low oil pressure
Starting/Charging System
24V, 45 Amp Charging alternator
24-volt electric starting motor
General
Parts book
Vibration damper
Lifting eyes
ALL
Air Inlet System
Turbocharger
Air cleaner - Non canister, disposable
Aftercooler core
Control Panel
GCCP 1.2
Cooling System
Radiator sight gauge
Thermostats and housing
Coolant drain valve
Jacket water pump, gear driven, centrifugal
Blower fan and fan drive with guards
Radiator, package mounted
Exhaust System
Exhaust manifold - dry
Fuel System
Fuel cooler
Primary fuel filter w/integral water separator and secondary filter, spin on
Integral tank base, 24 hours, UL142
Engine fuel transfer pump
Fuel priming pump
Generator Set
Complete system designed & built at ISO 9001:2000 certified facilities
Factory tested to design specifications at full load conditions
All protective devices and control functions simulated and checked
Generators and Generator Attachments
6 Leads
Voltage regulator (single phase sensing)
Easy access to AVR and terminals
Insulation system, Class H
Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
Terminal box, IP22 RHS facing, bottom cable entry
Standard winding protection for non-harsh environments with relative humidity ? 95%
IP23 Protection
Governing System
Cat electronic governor (ADEM A4)
Lube System
Oil filler and dipstick
Shallow oil pan
Oil filter, spin on
Oil cooler
Lubricating oil, CK-4 (10W-30)
Oil drain with valve
Fumes disposal to front of radiator
Mounting System
Includes lifting provisions and termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Protection
Safety shutoff - High water temperature
Safety shutoff - Overspeed
Safety shutoff - Low oil pressure
Starting/Charging System
24V, 45 Amp Charging alternator
24-volt electric starting motor
General
Parts book
Vibration damper
Lifting eyes
Optional Equipment
Air Inlet System
Air cleaner (Non canister disposable)
Bases, Mounting & Fuel Tanks
Audio & visual fuel alarm (@90% fuel level)
Integral tank base, 24 hours, UL142
5 Gallon Spill Containment
Overfill prevention valve
Fuel tank pill pipe & lockable cap
Wide Base - Skid
Circuit breaker
400A LSI
Auxiliary contacts
400A LS/I
800A LSI
600A LSI
1200A LS/I
800A LS/I
600A LS/I
1200A LSI
Control System
20A GFCI (Ground Fault Circuit Interrupter)
Ground fault relay
16 -light NFPA 99/110 Annunciator
Volt free contacts
Twist release, Red button emergency stop
100A Load center
Product link remote monitoring hardware
Audible alarm Gp
Earth (Ground) fault relay
Volt free contact
Remote E-Stop button
Discrete I/O module
Annunciators box
Local annunciator
Exhaust System
8" Muffler - 25 dBA attenuation
Flexible exhaust connection
Manifold and turbocharger guards
Generator
Space heater
Permanent magnet excitation (PMG) generator
Starting System
Jacket water heater
Standard battery set: 1000 CCA, 90 amp/hr.
Battery charger (UL Certified)
Oversize battery set, 1400 CCA, 200 amp/hr
General
Extended Service Coverage
Generator test report
CSA Certification
UL2200 Certification
Tool set
Circuit breakers
Single LSI motorised circuit breaker
Single LSI motorised circuit breaker
Auxiliary contacts
Neutral bar (208V)
Enclosures
E-Stop
Sound attenuated Level 2 enclosure (White)
AC & DC Source lights
Sound attenuated enclosure
Cooling System
Coolant heater
Stone guards
Jacket water heater with pump
Base / Fuel Tank
Audio & visual fuel alarm
Fuel System
Integral 8 hour tank base
Starting and Charging
Oversize battery set
Standard battery set
5 Amp Battery charger
Battery disconnect switch
Certifications
CSA 22.2
UL2200 Listed
Seismic
Lube System
Manual sump pump