Maximum Rating
80 ekW
Minimum Rating
80 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4
Length - Maximum
82.6in
Width - Maximum
43.3in
Height - Maximum
52.9in
Dry Weight - Genset (maximum)
950lb
Alternator System
3 Phase sensing
Anti-condensation heater
R Frame auxilliary winding
Permanent magnet excitation (PMG)
Circuit breakers
Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
Low coolant level shutdown
Coolant heater
Low coolant temperature alarm
Control Panel Options
Earth fault (2 wire only)
Overload shutdown via breaker
Earth leakage (2 wire only)
Volt free contacts
Panel mounted audible alarm
Battery charger
GCCP 1.2 Control panel
Control panel heater
Voltage adjust potentiometer
Emergency stop with key
Speed adjust potentiometer
Enclosures
Sound attenuated Level 2 enclosure
Fuel System
High fuel level alarm
Open set narrow tankbase
Low fuel level alarm
Bunded fuel tank
Low fuel level shutdown
Compact skidbase for open set
Skidbase for CALG enclosure sets
Global Certifications
Certification for CIS
Mounting Options
Battery removal
Industrial silencer
Electronic governor
External single point lift - enclosure
Silencer installation kit
Special Packing/Inspectons for Shipment
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
General - Accessories / Miscellaneous
Stone guards/rad trans flange
Packing case - canopied set
Packing case - compact set
Air Inlet System
Air cleaner; light duty with disposable element
Air cleaner
Cooling System
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Coolant drain line with valve
Control Panel
GCCP 1.2 Control panel
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Generator
Circuit breaker, IEC, 3 pole, mounted in tower panel
Voltage regulator (single phase sensing)
IP23 Protection
Segregated low voltage (AC/DC) wiring panel
12 Leads
Tower panel, IP22, bottom cable entry
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Lubricating oil
Oil drain line with valve
Mounting System
Includes lifting provision and drag points
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Starting/Charging System
Batteries
24V battery with rack and cables
General
Engine and alternator pre-paint, Caterpillar yellow
ALL
Air Inlet System
Air cleaner; light duty with disposable element
Air cleaner
Cooling System
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Coolant drain line with valve
Control Panel
GCCP 1.2 Control panel
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Generator
Circuit breaker, IEC, 3 pole, mounted in tower panel
Voltage regulator (single phase sensing)
IP23 Protection
Segregated low voltage (AC/DC) wiring panel
12 Leads
Tower panel, IP22, bottom cable entry
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Lubricating oil
Oil drain line with valve
Mounting System
Includes lifting provision and drag points
Termination points for coolant and lube oil drain lines
Captive linear vibration isolators between base and engine-generator
Starting/Charging System
Batteries
24V battery with rack and cables
General
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
3 Phase sensing
Anti-condensation heater
R Frame auxilliary winding
Permanent magnet excitation (PMG)
Circuit breakers
Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
Low coolant level shutdown
Coolant heater
Low coolant temperature alarm
Control Panel Options
Earth fault (2 wire only)
Overload shutdown via breaker
Earth leakage (2 wire only)
Volt free contacts
Panel mounted audible alarm
Battery charger
GCCP 1.2 Control panel
Control panel heater
Voltage adjust potentiometer
Emergency stop with key
Speed adjust potentiometer
Enclosures
Sound attenuated Level 2 enclosure
Fuel System
High fuel level alarm
Open set narrow tankbase
Low fuel level alarm
Bunded fuel tank
Low fuel level shutdown
Compact skidbase for open set
Skidbase for CALG enclosure sets
Global Certifications
Certification for CIS
Mounting Options
Battery removal
Industrial silencer
Electronic governor
External single point lift - enclosure
Silencer installation kit
Special Packing/Inspectons for Shipment
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
General - Accessories / Miscellaneous
Stone guards/rad trans flange
Packing case - canopied set
Packing case - compact set