Specifications
-
Standard/Optional Equipment
- Catalog
Standby Rating
50 kVA
Frequency
50 Hz
Emissions/Fuel Strategy
Low BSFC
Voltage
380 to 415 Volts
Speed
1500 rpm
Duty Cycle
Standby
Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Length - Maximum
89.7in
Width - Maximum
35.4in
Height - Maximum
52in
Dry Weight - Genset (maximum)
2273lb
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Alternator Requirements
Space heater
Fuel Storage
Integral dual wall
Single wall tank with containment
Low fuel level alarm
Low fuel level shutdown
High fuel level alarm
Genset Control
Battery charger
Volt free contacts for genset running
Volt free contacts for common alarm
Earth leakage
Earth fault
Emergency stop with key
USB to RS485 Communications device
Panel mounted audible alarm
Battery
Low coolant level shutdown
Standby Pack (Smart Jacket water heater, Battery charger)
Coolant heater
Circuit breaker
3-Pole and 4-Pole breakers
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
Package
Open Set
Engine
C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
GCCP 1.1
Governor
Mechanical governor
Alternator
Standard alternator
Base
Standard base
Enclosure
Cat GC enclosure
Air, Cooling & Exhaust
Enclosure / Industrial silencer
General
Engine and alternator pre-paint, Caterpillar yellow
Telematics
Cat® Product Link™ PL444 cellular
ALL
Engine
C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
GCCP 1.1
Governor
Mechanical governor
Alternator
Standard alternator
Base
Standard base
Enclosure
Cat GC enclosure
Air, Cooling & Exhaust
Enclosure / Industrial silencer
General
Engine and alternator pre-paint, Caterpillar yellow
Telematics
Cat® Product Link™ PL444 cellular
Optional Equipment
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Alternator Requirements
Space heater
Fuel Storage
Integral dual wall
Single wall tank with containment
Low fuel level alarm
Low fuel level shutdown
High fuel level alarm
Genset Control
Battery charger
Volt free contacts for genset running
Volt free contacts for common alarm
Earth leakage
Earth fault
Emergency stop with key
USB to RS485 Communications device
Panel mounted audible alarm
Battery
Low coolant level shutdown
Standby Pack (Smart Jacket water heater, Battery charger)
Coolant heater
Circuit breaker
3-Pole and 4-Pole breakers
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
Package
Open Set