Specifications
-
Standard/Optional Equipment
- Catalog
Standby Rating
30 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
Low BSFC
Voltage
220 to 480 Volts
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
19.25:1
Aspiration
Naturally Aspirated
Fuel System
Inline
Governor Type
Mechanical
Length - Maximum
76.6in
Width - Maximum
34.3in
Height - Maximum
48.7in
Dry Weight - Genset (maximum)
2114lb
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Alternator Requirements
Space heater
Fuel Storage
Integral dual wall tank
Low fuel level shutdown
Single wall tank with containment
Low fuel level alarm
High fuel level alarm
Genset Control
Battery charger
Volt free contacts for genset running
Volt free contacts for common alarm
Earth fault
Panel mounted audible alarm
USB to RS485 Communications device
Emergency stop with key
Earth leakage
Low coolant level shutdown
Coolant heater
Standby Pack (Smart Jacket water heater, Battery charger)
Standard Battery
Circuit breaker
3-Pole and 4-Pole breaker
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
Package
Open Set
Engine
C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
GCCP 1.1
Governor
Mechanical governor
Alternator
Standard alternator
Base Type
Standard base
Enclosure
Cat GC enclosure
Air Inlet
Standard air cleaner
General
Engine and alternator pre-paint, Caterpillar yellow
Telematics
Cat® Product Link™ PL444 cellular
ALL
Engine
C3.3, Inline 3 cylinder, 4 stroke diesel
Genset Control
GCCP 1.1
Governor
Mechanical governor
Alternator
Standard alternator
Base Type
Standard base
Enclosure
Cat GC enclosure
Air Inlet
Standard air cleaner
General
Engine and alternator pre-paint, Caterpillar yellow
Telematics
Cat® Product Link™ PL444 cellular
Optional Equipment
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Alternator Requirements
Space heater
Fuel Storage
Integral dual wall tank
Low fuel level shutdown
Single wall tank with containment
Low fuel level alarm
High fuel level alarm
Genset Control
Battery charger
Volt free contacts for genset running
Volt free contacts for common alarm
Earth fault
Panel mounted audible alarm
USB to RS485 Communications device
Emergency stop with key
Earth leakage
Low coolant level shutdown
Coolant heater
Standby Pack (Smart Jacket water heater, Battery charger)
Standard Battery
Circuit breaker
3-Pole and 4-Pole breaker
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
Package
Open Set