402

DE50 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

45 ekW

Duty Cycle

Standby

Emissions/Fuel Strategy

Non Regulated

Voltage

220 to 480 Volts

Frequency

60 Hz

Speed

1800 rpm

Minimum Rating

45 ekW

Engine Model

Cat® C3.3, In-line 3, 4-cycle diesel

Bore

4.1in

Stroke

5in

Displacement

201.4in³

Compression Ratio

17.25:1

Aspiration

Turbocharged

Fuel System

Inline

Governor Type

Mechanical

Length - Maximum

89.7in

Width - Maximum

35.4in

Height - Maximum

52in

Dry Weight - Genset (maximum)

1031lb

Certification

Certificate of Conformance

Australia, CIS, Gulf Certification

Auxiliary Supply Voltage

120V

Alternator Requirements

Space heater

Fuel Storage

Dual wall 8 hour fuel tank

Single wall tank with containment

Low fuel level shutdown

Low fuel level alarm

High fuel level alarm

Genset Control

Battery charger

Volt free contacts for common alarm

Volt free contacts for genset running

Earth leakage

Earth fault

USB to RS485 Communications device

Emergency stop with key

Panel mounted audible alarm

Coolant heater

Standby Pack (Smart Jacket water heater, Battery charger)

Battery

Low coolant level shutdown

Circuit breaker

3 Pole Circuit breaker 63A

3 Pole Circuit breaker 80A

3 Pole Circuit breaker 100A

3 Pole Circuit breaker 125A

3 Pole Circuit breaker 160A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 63A

4 Pole Circuit breaker 80A

4 Pole Circuit breaker 100A

4 Pole Circuit breaker 125A

4 Pole Circuit breaker 160A

4 Pole Circuit breaker 200A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

Testing & Packaging

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8PF

Engine

C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

GCCP 1.1

Governor

Mechanical governor

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Enclosure

Cat GC enclosure

Air, Cooling & Exhaust

Enclosure silencer

General

Engine and alternator pre-paint, Caterpillar yellow

ALL

Engine

C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

GCCP 1.1

Governor

Mechanical governor

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Enclosure

Cat GC enclosure

Air, Cooling & Exhaust

Enclosure silencer

General

Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Certification

Certificate of Conformance

Australia, CIS, Gulf Certification

Auxiliary Supply Voltage

120V

Alternator Requirements

Space heater

Fuel Storage

Dual wall 8 hour fuel tank

Single wall tank with containment

Low fuel level shutdown

Low fuel level alarm

High fuel level alarm

Genset Control

Battery charger

Volt free contacts for common alarm

Volt free contacts for genset running

Earth leakage

Earth fault

USB to RS485 Communications device

Emergency stop with key

Panel mounted audible alarm

Coolant heater

Standby Pack (Smart Jacket water heater, Battery charger)

Battery

Low coolant level shutdown

Circuit breaker

3 Pole Circuit breaker 63A

3 Pole Circuit breaker 80A

3 Pole Circuit breaker 100A

3 Pole Circuit breaker 125A

3 Pole Circuit breaker 160A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 63A

4 Pole Circuit breaker 80A

4 Pole Circuit breaker 100A

4 Pole Circuit breaker 125A

4 Pole Circuit breaker 160A

4 Pole Circuit breaker 200A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

Testing & Packaging

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8PF

    Send an Enquiry