402

DE165 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

150 ekW

Minimum Rating

150 ekW

Emissions/Fuel Strategy

Non Regulated

Voltage

220 to 480 Volts

Frequency

60 Hz

Speed

1800 rpm

Duty Cycle

Standby

Engine Model

C7.1 I-6, 4-Cycle Diesel

Bore

4.1in

Stroke

5.3in

Displacement

427.8in³

Compression Ratio

16.0:1

Aspiration

Turbocharged Air To Air Charge Cooled

Fuel System

Inline

Governor Type

Mechanical

Length - Maximum

130.9in

Width - Maximum

44.6in

Height - Maximum

65.6in

Dry Weight - Genset (maximum)

4043lb

Auxiliary Supply Voltage

120V

Certification

Australia, CIS, Gulf Certification

Certificate of Conformance

Alternator Requirements

Space heater

Fuel Storage

Dual wall 8 hour fuel tank

Single wall tank with containment

Low fuel level alarm

High fuel level alarm

Low fuel level shutdown

Genset Control

Battery charger

Volt free contacts for common alarm

Panel mounted audible alarm

Volt free contacts for genset running

Earth leakage

USB to RS485 Communications device

Earth fault

Emergency stop with key

Coolant heater

Battery

Low coolant level shutdown

Standby Pack (Smart Jacket water heater, Battery charger)

Fuel Systems

High fuel level alarm

Circuit breaker

3 Pole Circuit breaker 630A

4 Pole Circuit breaker 250A

4 Pole Circuit breaker 200A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 630A

4 Pole Circuit breaker 400A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

3 Pole Circuit breaker 400A

Testing & Packaging

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8PF

Engine

C7.1, Inline 6 cylinder, 4 stroke diesel

Control Panels

GCCP 1.1

Governor

Mechanical governor

Enclosure

Cat GC enclosure

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Air, Cooling & Exhaust

Enclosure silencer

General

Engine and alternator pre-paint, Caterpillar yellow

ALL

Engine

C7.1, Inline 6 cylinder, 4 stroke diesel

Control Panels

GCCP 1.1

Governor

Mechanical governor

Enclosure

Cat GC enclosure

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Air, Cooling & Exhaust

Enclosure silencer

General

Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Auxiliary Supply Voltage

120V

Certification

Australia, CIS, Gulf Certification

Certificate of Conformance

Alternator Requirements

Space heater

Fuel Storage

Dual wall 8 hour fuel tank

Single wall tank with containment

Low fuel level alarm

High fuel level alarm

Low fuel level shutdown

Genset Control

Battery charger

Volt free contacts for common alarm

Panel mounted audible alarm

Volt free contacts for genset running

Earth leakage

USB to RS485 Communications device

Earth fault

Emergency stop with key

Coolant heater

Battery

Low coolant level shutdown

Standby Pack (Smart Jacket water heater, Battery charger)

Fuel Systems

High fuel level alarm

Circuit breaker

3 Pole Circuit breaker 630A

4 Pole Circuit breaker 250A

4 Pole Circuit breaker 200A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 630A

4 Pole Circuit breaker 400A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

3 Pole Circuit breaker 400A

Testing & Packaging

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8PF