Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
500 ekW
Minimum Rating
500 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby
Engine Model
C13 In-line 6, 4-cycle diesel
Bore
5.1in
Stroke
6.2in
Displacement
763in³
Compression Ratio
15.8:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
EUI
Governor Type
Adem™A4
Length - Maximum
122in
Width - Maximum
52.7in
Height - Maximum
85.4in
Dry Weight - Genset (maximum)
6693lb
Control panel
Speed and Voltage adjust potentiometers
PLG 4G/3G/Ethernet
Annunciator
Emergency E-Stop
Enclosure
Cat GC enclosure
Electrical Options
4 Pole Circuit breaker
Auxiliary contacts
Padlockable circuit breaker
Battery charger
Wet battery
Circuit breakers
Shunt trip for IEC circuit breaker
4 Pole (IEC-100% rated) Circuit breaker - Motorised
Circuit breaker (IEC) Auxiliary contacts
Alternator
Space heater
AVR
Exhaust System
Industrial silencer
10 dBA Attenuation silencer
6 and 8 inch flange GP
Flexible 8 inch exhaust fittings
6 and 8 inch elbow kit
10, 25 and 35 dBA attenuation
Air inlet system
Single stage air filter
Dual element air filter
Certifications
EU Certificate of Conformance (CE)
EAC Certification
Extended service coverage
3, 4, 5 and 10 Years
Fuel System
Dual wall 8 hour fuel tank
Single wall 8 hour fuel tank with spill containment
Low fuel level shutdown
Low and high fuel level alarms
Fuel transfer system controls
Manual fuel transfer pump
Integral dual wall fuel tank base
Generator and Attachments
LC frame generator
Ingress protection
LC CIP generator
A Frame CIP generator
Permanent magnet excitation (PMG) generator
A Frame oversize generator
Space heaters
Lube System
Manual sump pump
Mounting System
Narrow skid base
starting / Charging System
Jacket water heater
Battery disconnect switch
5 Amp single Battery charger
Engine
Cat® C13 Inline 6 cylinder, 4 stroke diesel
Control Panels
GCCP 1.1
Governor
Mechanical governor
Alternator
A Frame standard alternator
Fuel Storage
Single wall 8 hour fuel tank
Cooling System
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Electrical Options
3 Pole Circuit breaker
Neutral earth link
24 Volt battery with rack and cables
Air inlet system
Air cleaner; light duty with disposable element
Lube system
Lubricating oil
Oil drain line with valve
Mounting system
Captive linear vibration isolators
Lifting provision and drag points
General
Engine and alternator pre paint, Caterpillar yellow
Engine and alternator pre-paint, Caterpillar yellow
Generator and Attachments
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Packaged Generator Set
Service indicator
Radiator package mounted
Disposable air filter
Coolant level sight gauge
Coolant drain line with valve
Low coolant level sensor
Governing System
Cat electronic governor (ADEM A4)
Lube System
Lubricating oil
Oil cooler
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator
Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
24V battery with rack and cables
ALL
Engine
Cat® C13 Inline 6 cylinder, 4 stroke diesel
Control Panels
GCCP 1.1
Governor
Mechanical governor
Alternator
A Frame standard alternator
Fuel Storage
Single wall 8 hour fuel tank
Cooling System
Radiator and cooling fan with guards
Fan drive, battery charging alternator drive
Electrical Options
3 Pole Circuit breaker
Neutral earth link
24 Volt battery with rack and cables
Air inlet system
Air cleaner; light duty with disposable element
Lube system
Lubricating oil
Oil drain line with valve
Mounting system
Captive linear vibration isolators
Lifting provision and drag points
General
Engine and alternator pre paint, Caterpillar yellow
Engine and alternator pre-paint, Caterpillar yellow
Generator and Attachments
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Packaged Generator Set
Service indicator
Radiator package mounted
Disposable air filter
Coolant level sight gauge
Coolant drain line with valve
Low coolant level sensor
Governing System
Cat electronic governor (ADEM A4)
Lube System
Lubricating oil
Oil cooler
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator
Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
24V battery with rack and cables
Optional Equipment
Control panel
Speed and Voltage adjust potentiometers
PLG 4G/3G/Ethernet
Annunciator
Emergency E-Stop
Enclosure
Cat GC enclosure
Electrical Options
4 Pole Circuit breaker
Auxiliary contacts
Padlockable circuit breaker
Battery charger
Wet battery
Circuit breakers
Shunt trip for IEC circuit breaker
4 Pole (IEC-100% rated) Circuit breaker - Motorised
Circuit breaker (IEC) Auxiliary contacts
Alternator
Space heater
AVR
Exhaust System
Industrial silencer
10 dBA Attenuation silencer
6 and 8 inch flange GP
Flexible 8 inch exhaust fittings
6 and 8 inch elbow kit
10, 25 and 35 dBA attenuation
Air inlet system
Single stage air filter
Dual element air filter
Certifications
EU Certificate of Conformance (CE)
EAC Certification
Extended service coverage
3, 4, 5 and 10 Years
Fuel System
Dual wall 8 hour fuel tank
Single wall 8 hour fuel tank with spill containment
Low fuel level shutdown
Low and high fuel level alarms
Fuel transfer system controls
Manual fuel transfer pump
Integral dual wall fuel tank base
Generator and Attachments
LC frame generator
Ingress protection
LC CIP generator
A Frame CIP generator
Permanent magnet excitation (PMG) generator
A Frame oversize generator
Space heaters
Lube System
Manual sump pump
Mounting System
Narrow skid base
starting / Charging System
Jacket water heater
Battery disconnect switch
5 Amp single Battery charger