402

DE660 GC (50 Hz) Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

660 kVA

Minimum Rating

660 kVA

Emissions/Fuel Strategy

Non Regulated

Voltage

380 to 415 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby

Engine Model

C15 In-line 6, 4-cycle diesel

Bore

5.4in

Stroke

6.8in

Displacement

928in³

Compression Ratio

16.1:1

Aspiration

Turbocharged Air-to-Air Aftercooled

Fuel System

EUI

Governor Type

Adem™A4

Length - Maximum

131in

Width - Maximum

60.6in

Height - Maximum

86.1in

Dry Weight - Genset (maximum)

8364lb

Control panel

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Exhaust

Industrial, residential, critical mufflers

Enclosure

Cat GC enclosure

Generator

Oversize and premium generators

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Anti-condensation heater

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Alternator

Space heater

AVR

Generator and Attachments

Oversize A Frame generator

LC frame generator

LC frame CIP generator

Ingress protection

CIP A Frame generator

Permanent magnet excitation (PMG) generator

Oversize LC frame generator

Space heaters

Starting/Charging

Oversize batteries

Charging alternator

Jacket water heater

Battery chargers

Heavy duty starting system

24 Volt battery with rack and cables

Air inlet system

Single stage air filter

Dual element air filter

Certifications

EU Certificate of Conformance (CE)

EAC Certification

General

The following options are based on regional and product configuration:

Sound attenuated, weather protective or high ambient weather protective enclosure

UL 2200 package

CSA Certification

Narrow, wide or skid base

EEC Declaration of Conformity

EU Certificate of Conformance (CE)

Single or dual wall sub-base fuel tanks

Single or dual wall integral fuel tanks

Automatic transfer switches (ATS)

Integral & sub-base UL listed dual wall fuel tanks

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

Extended service coverage

3, 4, 5 and 10 Years

Enclosures

High ambient sound attenuated enclosures

Sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

6 and 8 inch elbow kit

Flexible exhaust fittings

6 and 8 inch flange GP

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Engine mounted muffler

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Manual fuel transfer pump

Dual wall fuel tank base

Fuel transfer system controls

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

5 Amp single Battery charger

Jacket water heater

Battery disconnect switch

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Air Inlet

Air cleaner

Control Panels

GCCP 1.1

Governor

Mechanical governor

Cooling

Package mounted radiator

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Fuel

Fuel priming pump

Primary fuel filter with integral water separator

Secondary fuel filters

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Air inlet system

Air cleaner; light duty with disposable element

Generator

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

IP23 Protection

Lube system

Lubricating oil

Oil drain line with valve

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

General

Engine and alternator pre paint, Caterpillar yellow

Engine and alternator pre paint, Caterpillar yellow

Power Termination

Busbar

Generator and Attachments

Power center, IP22

Segregated low voltage (AC/DC) wiring panel

Optional LC Frame generator - IP23 Protection

Integrated voltage regulator (IVR)

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil cooler

Oil drain valves

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

ALL

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Air Inlet

Air cleaner

Control Panels

GCCP 1.1

Governor

Mechanical governor

Cooling

Package mounted radiator

Alternator

A Frame standard alternator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Fuel

Fuel priming pump

Primary fuel filter with integral water separator

Secondary fuel filters

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Air inlet system

Air cleaner; light duty with disposable element

Generator

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

IP23 Protection

Lube system

Lubricating oil

Oil drain line with valve

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

General

Engine and alternator pre paint, Caterpillar yellow

Engine and alternator pre paint, Caterpillar yellow

Power Termination

Busbar

Generator and Attachments

Power center, IP22

Segregated low voltage (AC/DC) wiring panel

Optional LC Frame generator - IP23 Protection

Integrated voltage regulator (IVR)

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil cooler

Oil drain valves

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Optional Equipment

Control panel

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Exhaust

Industrial, residential, critical mufflers

Enclosure

Cat GC enclosure

Generator

Oversize and premium generators

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Anti-condensation heater

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Alternator

Space heater

AVR

Generator and Attachments

Oversize A Frame generator

LC frame generator

LC frame CIP generator

Ingress protection

CIP A Frame generator

Permanent magnet excitation (PMG) generator

Oversize LC frame generator

Space heaters

Starting/Charging

Oversize batteries

Charging alternator

Jacket water heater

Battery chargers

Heavy duty starting system

24 Volt battery with rack and cables

Air inlet system

Single stage air filter

Dual element air filter

Certifications

EU Certificate of Conformance (CE)

EAC Certification

General

The following options are based on regional and product configuration:

Sound attenuated, weather protective or high ambient weather protective enclosure

UL 2200 package

CSA Certification

Narrow, wide or skid base

EEC Declaration of Conformity

EU Certificate of Conformance (CE)

Single or dual wall sub-base fuel tanks

Single or dual wall integral fuel tanks

Automatic transfer switches (ATS)

Integral & sub-base UL listed dual wall fuel tanks

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

Extended service coverage

3, 4, 5 and 10 Years

Enclosures

High ambient sound attenuated enclosures

Sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

6 and 8 inch elbow kit

Flexible exhaust fittings

6 and 8 inch flange GP

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Engine mounted muffler

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Manual fuel transfer pump

Dual wall fuel tank base

Fuel transfer system controls

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

5 Amp single Battery charger

Jacket water heater

Battery disconnect switch

    Send an Enquiry