Specifications
-
Standard/Optional Equipment
- Catalog
Rating Prime
550 kVA
Frequency
50/60 Hz
Voltage
220 - 480 V
Fuel/Emissions Strategy
EU Stage V
Engine
Cat® C18
Fuel
Diesel
Width
80.3in
Height
90.5in
Length
213.3in
Weight - With Lube Oil and Coolant
14860lb
100% Load 60 Hz
34.3gal/hr
100% Load 50 Hz
33.4gal/hr
Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz)
79.19
75% Load 60 Hz
26.13gal/hr
75% Load 50 Hz
24.9gal/hr
Cat C18 Diesel Engine
Turbocharged, ATAAC
Generator
LC6114K Frame
Air Filter
Cyclonic/paper with dust cup and service indicator
Cat Connect remote monitoring
Provides package monitoring and management
Cooling System
Package mounted radiator with vertical air discharge. Filled from factory
Charging / Starting System
24V heavy duty starting motor and charging alternator c/w battery isolator
Fuel System
24 hour dual wall fuel tank with 3 way directional valve for external supply
Control Panel
XQCP set mounted controller.
Distribution
Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off
Structure
Heavy Duty steel base frame with integral fuel tank. Fork lift pockets. Dragging bars. Lifting frame and 4 point lift. base frame is wider than enclosure to protect generator set during transportation.
Enclosure
Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance
Exhaust
Integrated spark arresting silencer
Lube Oil
On engine primary and secondary oil filters. Filled from factory
General
Factory tested and inspected
ALL
Cat C18 Diesel Engine
Turbocharged, ATAAC
Generator
LC6114K Frame
Air Filter
Cyclonic/paper with dust cup and service indicator
Cat Connect remote monitoring
Provides package monitoring and management
Cooling System
Package mounted radiator with vertical air discharge. Filled from factory
Charging / Starting System
24V heavy duty starting motor and charging alternator c/w battery isolator
Fuel System
24 hour dual wall fuel tank with 3 way directional valve for external supply
Control Panel
XQCP set mounted controller.
Distribution
Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off
Structure
Heavy Duty steel base frame with integral fuel tank. Fork lift pockets. Dragging bars. Lifting frame and 4 point lift. base frame is wider than enclosure to protect generator set during transportation.
Enclosure
Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance
Exhaust
Integrated spark arresting silencer
Lube Oil
On engine primary and secondary oil filters. Filled from factory
General
Factory tested and inspected