Specifications
-
Standard/Optional Equipment
- Catalog
Rating Range
100 - 3000 A
Transfer Type
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type
Contactor
Product nodes
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Rated Voltage and Frequency
200-480VAC, 50/60 Hz
Phase system
Single and Three
Number of poles
2, 3 and 4
Neutral configuration
Solid neutral, Switched neutral, Overlapping neutral (100-1200A only)
Product type
Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II)
Options
Options not available
Control
Color touchscreen
Voltage and frequency settings: Pick up and Drop out
Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
Additional Features
LED indications for ATS, S1 and S2 status
Programmable digital inputs/outputs
Auto config (voltage, frequency, phase system)
Source priority (Source 1/2, No priority)
Manual re-transfer
In-phase monitor (synchro check)
Genset exercising: on-load, off-load
In-built power meter module
Load shedding
Real time clock
Event log
Predictive maintenance
Voltage and current harmonics measuring
Accessories
Auxiliary contacts for position indication
Digital input/output modules (factory programmed)
12-24 VDC aux supply module for controller
Communication modules
Connectivity Capability
Modbus RTU (RS-485)
Modbus/TCP
Profibus DP
ProfiNet Yes
DeviceNet
Ethernet IP
Applications
Utility - Utility
Utility - Generator
UL short circuit withstand ratings
Coordinated breaker WCR
Time-based WCR
Short-time ratings
ALL
Control
Color touchscreen
Voltage and frequency settings: Pick up and Drop out
Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
Additional Features
LED indications for ATS, S1 and S2 status
Programmable digital inputs/outputs
Auto config (voltage, frequency, phase system)
Source priority (Source 1/2, No priority)
Manual re-transfer
In-phase monitor (synchro check)
Genset exercising: on-load, off-load
In-built power meter module
Load shedding
Real time clock
Event log
Predictive maintenance
Voltage and current harmonics measuring
Accessories
Auxiliary contacts for position indication
Digital input/output modules (factory programmed)
12-24 VDC aux supply module for controller
Communication modules
Connectivity Capability
Modbus RTU (RS-485)
Modbus/TCP
Profibus DP
ProfiNet Yes
DeviceNet
Ethernet IP
Applications
Utility - Utility
Utility - Generator
UL short circuit withstand ratings
Coordinated breaker WCR
Time-based WCR
Short-time ratings
Optional Equipment
Options
Options not available