Specifications
-
Standard/Optional Equipment
- Catalog
Continuous Rating
400 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
43.1% / 42.1%
Frequency
50 / 60 Hz
RPM
1500 or 1800 rpm
Engine Model
CG132-8
Displacement
1067.9in³
Aspiration
TA
Bore
5.2in
Stroke
6.3in
Length
122in
Width
70in
Height
85in
Dry Weight - Genset
12610lb
Cooling
CHP skid
Grid Code Compliance
50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands
Air Inlet
One-element single-stage air cleaner with enclosure and sevice indicator
Turbocharger with a water-cooled bearing case for all cylinder
Control Panels
TPEM (Total Plant & Energy Management System)
Cooling
flange connections for JW inlet and outlet
Electrical jacket water and aftercooler coolant pump
Jacket water and SCAC thermostats
ANSI/DN customer flange connections for JW inlet and outlet
Exhaust
Exhaust waste gate for the CG132B-16
Closed crankcase ventilation system
PEARL/Low resistence exhaust system
Fuel system
Independently controlled cylinder monitoring and ignition system
Electronic fuel metering valve
Pre-chamber spark plugs
Generator
Anti-condensation space heater
Reactive droop
closed-coupled generator result in no torque transmission to the base frame
Winding temperature detectors
Busbar connections
3-phase sensing and KVAR/PF control
grid code generator
Starting/Charging
24V starting motors
Battery disconnect switch
General
Crankshaft vibration damper and guard
ALL
Air Inlet
One-element single-stage air cleaner with enclosure and sevice indicator
Turbocharger with a water-cooled bearing case for all cylinder
Control Panels
TPEM (Total Plant & Energy Management System)
Cooling
flange connections for JW inlet and outlet
Electrical jacket water and aftercooler coolant pump
Jacket water and SCAC thermostats
ANSI/DN customer flange connections for JW inlet and outlet
Exhaust
Exhaust waste gate for the CG132B-16
Closed crankcase ventilation system
PEARL/Low resistence exhaust system
Fuel system
Independently controlled cylinder monitoring and ignition system
Electronic fuel metering valve
Pre-chamber spark plugs
Generator
Anti-condensation space heater
Reactive droop
closed-coupled generator result in no torque transmission to the base frame
Winding temperature detectors
Busbar connections
3-phase sensing and KVAR/PF control
grid code generator
Starting/Charging
24V starting motors
Battery disconnect switch
General
Crankshaft vibration damper and guard
Optional Equipment
Cooling
CHP skid
Grid Code Compliance
50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands