Specifications
-
Standard/Optional Equipment
- Catalog
Prime Power Rating
1825 ekW
Continuous Rating
1640 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 to 13800 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Prime, Continuous
Maximum Rating
1825 ekW
Minimum Rating
1640 ekW
Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69in
Stroke
7.48in
Displacement
4210.64in
Compression Ratio
14.0:1
Aspiration
TA
Fuel System
Electronic unit injection
Governor Type
Adem™4
Length - Minimum
264.3in
Length - Maximum
264.3in
Width - Minimum
90.1in
Width - Maximum
90.1in
Height - Minimum
94.1in
Height - Maximum
94.1in
Dry Weight - Genset (minimum)
33300lb
Dry Weight - Genset (maximum)
33300lb
Exhaust
Exhaust mufflers
Air Inlet System
Standard ambient radiators
Dual element air cleaner
Standard ambient ATAAC radiators
Single element filter
Optional radiator arrangements
Generator
Anti-condensation heater
Permanent magnet excitation (PMG)
Oversize and premium generators
Internal excitation (IE)
Control Panels
EMCP 4.4
Load share module
Digital I/O module
Generator main terminal box
Remote monitoring software
Vandal proof panel cover
Generator temperature monitoring & protection
Empty upper box
Cable Shroud
Annunciator - local
Digital I/O module
Annunciator - remote
Side extension box
Cooling System
Coolant
Water level switch gauges
Crankcase Systems
No explosion relief valves
Explosion relief valves
Crankcase ventilation systems
Crankcase protection groups:
Mounting
Rubber anti-vibration mounts
IBC isolators
Exhaust System
Flange and exhaust expanders
Flexible fittings
Tier 4 lean emissions moDual
Flanges
Elean emission parts
Tier 4 dosing cabinet
Exhaust offset
Mufflers
Tier 4 clean emission MOD kits
Y Adapters
Elbows>
Starting/Charging
Oversize batteries
Charging alternator
Heavy duty starting system
Jacket water heater
Battery chargers
General
CSA Certification
EEC Declaration of Conformity
Automatic transfer switches (ATS)
UL 2200 package
Integral & sub-base UL listed dual wall fuel tanks
EU Certificate of Conformance (CE)
Integral & sub-base fuel tanks
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Enclosures: Sound attenuated, weather protective
The following options are based on regional and product configuration:
Extended Service Coverage
Platinum, Silver and Gold coverage
Fuel System
Primary fuel filter
Fuel priming pumps (Tier 4)
Gas fuel filter
Generators and Attachments
Generator conversions
Hi voltage optional attachments
2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
Generators high voltage
Differential current transformers
1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
Alternator air cleaner
1800 Frame
Space heater kit
3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
Instrumentation
Pyrometer and termocouples
Lube System
Oil level regulator
Prelube pump groups
Lube oil in standard sump
Mounting System
IBC vibration isolators
Puck style low efficiency isolators
Spring type vibration isolators
Power Connections
Center post busbars
Cable entry - rear
Rear power connections
Cable entry - right side
Cable entry - left side
Grounding groups
Neutral ground connections
Right side power connections
left side power connections
Power Termination
Circuit breakers - LV Packages
2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
Circuit breakers, IEC compliant
Circuit breakers, UL listed
1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
Special Tests / Reports
Generator set report
PGS Test report @ 0.8 power factor
Fuel consumption test
Torsional vibration analysis
Seismic Certifications
PGS Test report @ 1.0 power factor
Standard engine test
OSPD Certification
Starting / Charging
10, 20, 35 Amp Battery chargers
Engine barring device
Batteries, racks and cables
Jacket water heaters
Air starting motors with control and silencer
Electric starting motors
Starter cover
50 Amp NFPA battery charger
Air pressure regulator
Air Inlet System
Air cleaner, single element canister type
Cooling
Package mounted radiator
Exhaust
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Secondary fuel filters
Control System
Generator set packages include Caterpillars voltage regulator
6 Customer programmable digital inputs
Controls:
Low coolant temperature
Auto/start/stop control
Low coolant level
Customer data link (Modbus RTU)
PLC functionality
kVA (per phase, average & percent)
Reverse power (kW) (32)
Alarm acknowledge
kW (per phase, average & percent)
kW-hr (total)
Lamp test
RPM
Volts (L-L & L-N), frequency (Hz)
Generator phase sequence
Operating hours
kVAr-hr (total)
True RMS AC metering, 3-phase, +/-2% accuracy
Over/under frequency (81 o/u)
Accessory module data link
Number of I/O varies on options selected
High coolant temperature
Overspeed
1 Programmable digital outputs
Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
DC volts
Reverse reactive power (kVAr) (32RV)
Amps (per phase & average)
Oil pressure (psi, kPa or bar)
Coolant temperature
Failure to start (overcrank)
3 Analog inputs
Power factor (per phase & average)
EMCP 4.3
kVAr (per phase, average & percent)
Cat connect
Engine cool-down timer
1 Programmable relay outputs (Form C)
Environmental sealed front face
Warning/shutdown with common LED indication of shutdowns for:
24 Volt DC operation
Over/under voltage (27/59)
Emergency stop pushbutton
Limiter and exciter diode monitor
Generator mounted - rear facing
Digital indication for:
Text alarm/event descriptions
Customizable screens
Load histogram feature
Emergency stop
Serial annunciator module data link
Programmable protective relaying functions:
Low oil pressure
Communications:
Speed adjust
Engine cycle crank
4 Programmable relay outputs (Form A)
Overcurrent (50/51)
Power Termination
Busbar
Control Panel
Cat ECS Genset controller
Cooling System
Package mounted radiator
Exhaust System
Dry exhaust manifold
Flanged faced outlet(s)
Fuel System
Fuel cooler; not included with packages without radiator
Flexible fuel lines - shipped loose
Secondary fuel filters
Fuel priming pump
General
SAE standard rotation
Flywheel and Flywheel housing-SAE No. 00
Paint - Caterpillar yellow except rails and radiators gloss black
RH service
Generators and Attachments
Matched to the performance and output characteristics of Cat engines
Random wound
IP23 Protection
Anti-condensation space heater
3 Phase brushless, Salient pole
HV:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
LV
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
6 Lead
Form wound
Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
Winding temperature detectors
MV:
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Governing System
ADEM A3
Lube System
Oil drain lines and valve
Lubricating oil
Integral lube Oil cooler
Oil filter, filler and dipstick
Fumes disposal
Gear type lube oil pump
Mounting System
Rails - Engine/generator/radiator mounting.
Rubber anti-vibration mounts - shipped loose
Anti-vibration mounts (shipped loose)
Starting System
Battery disconnect switch
24 Volt electric starting motor
45 Amp Charging alternator
Battery and battery rack w/cables
ALL
Air Inlet System
Air cleaner, single element canister type
Cooling
Package mounted radiator
Exhaust
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Secondary fuel filters
Control System
Generator set packages include Caterpillars voltage regulator
6 Customer programmable digital inputs
Controls:
Low coolant temperature
Auto/start/stop control
Low coolant level
Customer data link (Modbus RTU)
PLC functionality
kVA (per phase, average & percent)
Reverse power (kW) (32)
Alarm acknowledge
kW (per phase, average & percent)
kW-hr (total)
Lamp test
RPM
Volts (L-L & L-N), frequency (Hz)
Generator phase sequence
Operating hours
kVAr-hr (total)
True RMS AC metering, 3-phase, +/-2% accuracy
Over/under frequency (81 o/u)
Accessory module data link
Number of I/O varies on options selected
High coolant temperature
Overspeed
1 Programmable digital outputs
Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
DC volts
Reverse reactive power (kVAr) (32RV)
Amps (per phase & average)
Oil pressure (psi, kPa or bar)
Coolant temperature
Failure to start (overcrank)
3 Analog inputs
Power factor (per phase & average)
EMCP 4.3
kVAr (per phase, average & percent)
Cat connect
Engine cool-down timer
1 Programmable relay outputs (Form C)
Environmental sealed front face
Warning/shutdown with common LED indication of shutdowns for:
24 Volt DC operation
Over/under voltage (27/59)
Emergency stop pushbutton
Limiter and exciter diode monitor
Generator mounted - rear facing
Digital indication for:
Text alarm/event descriptions
Customizable screens
Load histogram feature
Emergency stop
Serial annunciator module data link
Programmable protective relaying functions:
Low oil pressure
Communications:
Speed adjust
Engine cycle crank
4 Programmable relay outputs (Form A)
Overcurrent (50/51)
Power Termination
Busbar
Control Panel
Cat ECS Genset controller
Cooling System
Package mounted radiator
Exhaust System
Dry exhaust manifold
Flanged faced outlet(s)
Fuel System
Fuel cooler; not included with packages without radiator
Flexible fuel lines - shipped loose
Secondary fuel filters
Fuel priming pump
General
SAE standard rotation
Flywheel and Flywheel housing-SAE No. 00
Paint - Caterpillar yellow except rails and radiators gloss black
RH service
Generators and Attachments
Matched to the performance and output characteristics of Cat engines
Random wound
IP23 Protection
Anti-condensation space heater
3 Phase brushless, Salient pole
HV:
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
LV
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
6 Lead
Form wound
Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
Winding temperature detectors
MV:
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
Governing System
ADEM A3
Lube System
Oil drain lines and valve
Lubricating oil
Integral lube Oil cooler
Oil filter, filler and dipstick
Fumes disposal
Gear type lube oil pump
Mounting System
Rails - Engine/generator/radiator mounting.
Rubber anti-vibration mounts - shipped loose
Anti-vibration mounts (shipped loose)
Starting System
Battery disconnect switch
24 Volt electric starting motor
45 Amp Charging alternator
Battery and battery rack w/cables
Optional Equipment
Exhaust
Exhaust mufflers <!--(except Tier 4)-->
Air Inlet System
Standard ambient radiators
Dual element air cleaner
Standard ambient ATAAC radiators
Single element filter
Optional radiator arrangements
Generator
Anti-condensation heater
Permanent magnet excitation (PMG)
Oversize and premium generators
Internal excitation (IE)
Control Panels
EMCP 4.4
Load share module
Digital I/O module
Generator main terminal box
Remote monitoring software
Vandal proof panel cover
Generator temperature monitoring & protection
Empty upper box
Cable Shroud
Annunciator - local
Digital I/O module
Annunciator - remote
Side extension box
Cooling System
Coolant
Water level switch gauges
Crankcase Systems
No explosion relief valves
Explosion relief valves
Crankcase ventilation systems
Crankcase protection groups:
Mounting
Rubber anti-vibration mounts
IBC isolators
Exhaust System
Flange and exhaust expanders
Flexible fittings
Tier 4 lean emissions moDual
Flanges
Elean emission parts
Tier 4 dosing cabinet
Exhaust offset
Mufflers
Tier 4 clean emission MOD kits
Y Adapters
Elbows>
Starting/Charging
Oversize batteries
Charging alternator
Heavy duty starting system
Jacket water heater
Battery chargers
General
CSA Certification
EEC Declaration of Conformity
Automatic transfer switches (ATS)
UL 2200 package
Integral & sub-base UL listed dual wall fuel tanks
EU Certificate of Conformance (CE)
Integral & sub-base fuel tanks
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Enclosures: Sound attenuated, weather protective
The following options are based on regional and product configuration:
Extended Service Coverage
Platinum, Silver and Gold coverage
Fuel System
Primary fuel filter
Fuel priming pumps (Tier 4)
Gas fuel filter
Generators and Attachments
Generator conversions
Hi voltage optional attachments
2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
Generators high voltage
Differential current transformers
1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
Alternator air cleaner
1800 Frame
Space heater kit
3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
Instrumentation
Pyrometer and termocouples
Lube System
Oil level regulator
Prelube pump groups
Lube oil in standard sump
Mounting System
IBC vibration isolators
Puck style low efficiency isolators
Spring type vibration isolators
Power Connections
Center post busbars
Cable entry - rear
Rear power connections
Cable entry - right side
Cable entry - left side
Grounding groups
Neutral ground connections
Right side power connections
left side power connections
Power Termination
Circuit breakers - LV Packages
2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
Circuit breakers, IEC compliant
Circuit breakers, UL listed
1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
Special Tests / Reports
Generator set report
PGS Test report @ 0.8 power factor
Fuel consumption test
Torsional vibration analysis
Seismic Certifications
PGS Test report @ 1.0 power factor
Standard engine test
OSPD Certification
Starting / Charging
10, 20, 35 Amp Battery chargers
Engine barring device
Batteries, racks and cables
Jacket water heaters
Air starting motors with control and silencer
Electric starting motors
Starter cover
50 Amp NFPA battery charger
Air pressure regulator