402

3412C Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Standby Rating

750/800/900 kVA

Prime Power Rating

680/725/810 kVA

Emissions/Fuel Strategy

Low BSFC

Voltage

380 to 415 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby, Prime

Engine Model

3412C TA, V-12, 4-Stroke Water-Cooled Diesel

Bore

5.4in

Stroke

6in

Displacement

1648.86in³

Compression Ratio

13:01

Aspiration

TA

Fuel System

Pump and Lines

Governor Type

ADEM™ A5

Length - Maximum

162.4in

Width - Minimum

75in

Width - Maximum

78.3in

Height - Maximum

75in

Dry Weight - Genset (minimum)

12039lb

Dry Weight - Genset (maximum)

13030lb

Air Inlet System

Heavy duty air cleaners

Dual element air cleaners

Open element air cleaners

Circuit breakers

1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip

1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip

Control Panel

Generator temperature monitoring package

EMCP 4.4

First local annunicators

Vandal proof panel door

Remote custom annunicator

EMCP 4.3 , EMCP 4.2B

Local discrete I/O package

Common alarm/shutdown relay

Ground fault relay

Generator running VFC

Cooling System

Radiator duct flange

Jacket water heaters

European Certifications

Eurasian Conformity (EAC) mark

Exhaust System

Through wall installation kit

Mufflers

Manifold and turbocharger guards

Elbow kit

Generator and Attachments

Permanent magnet excitation (PMG)

Space heater

Digital voltage regulator

Lube System

Manual sump pump

Mounting System

Fuel tank base (1200 ltr)

Starting / Charging

Oversize batteries

Battery chargers

Battery disconnect switch

Heavy duty starting system

Governing System

Electronic Governor (ADEM™ A5)

Air Inlet System

Air cleaner, single element canister type with service indicator

Control Panel

EMCP 4.2B

Digital I/O module

Remote Serial annunciator

Local annunciator

Emergency stop pushbutton

2 Programmable digital outputs

Remote CAN annunciator

Cooling System

Radiator with guard (Sized for 50 degrees C)

Coolant level shutdown

Coolant drain line with valve, piped to edge of base

Fan and belt guards

Caterpillar extended life coolant

Exhaust System

Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose

Fuel System

Primary and Secondary fuel filters

Fuel priming pump

Flexible fuel lines terminated on base

Water seperator

Generator and Attachments

Busbar termination

3-phase sensing

Class H insulation

Reactive droop

VR6 voltage regulator

SR4B self excited

12 Leads

Class F temperature rise

Governing System

Cat electronic governor

Lube System

Oil drain line with valve, piped to edge of base

Lubricating oil

Oil filter

Fumes disposal, piped to front of radiator

Mounting System

Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

45A Charging alternator

Battery with rack, cables

Fuel shutoff solenoid

24 volt starting motor

Telematics

Ethernet / Cellular

ALL

Air Inlet System

Air cleaner, single element canister type with service indicator

Control Panel

EMCP 4.2B

Digital I/O module

Remote Serial annunciator

Local annunciator

Emergency stop pushbutton

2 Programmable digital outputs

Remote CAN annunciator

Cooling System

Radiator with guard (Sized for 50 degrees C)

Coolant level shutdown

Coolant drain line with valve, piped to edge of base

Fan and belt guards

Caterpillar extended life coolant

Exhaust System

Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose

Fuel System

Primary and Secondary fuel filters

Fuel priming pump

Flexible fuel lines terminated on base

Water seperator

Generator and Attachments

Busbar termination

3-phase sensing

Class H insulation

Reactive droop

VR6 voltage regulator

SR4B self excited

12 Leads

Class F temperature rise

Governing System

Cat electronic governor

Lube System

Oil drain line with valve, piped to edge of base

Lubricating oil

Oil filter

Fumes disposal, piped to front of radiator

Mounting System

Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

45A Charging alternator

Battery with rack, cables

Fuel shutoff solenoid

24 volt starting motor

Telematics

Ethernet / Cellular

Optional Equipment

Air Inlet System

Heavy duty air cleaners

Dual element air cleaners

Open element air cleaners

Circuit breakers

1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip

1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip

Control Panel

Generator temperature monitoring package

EMCP 4.4

First local annunicators

Vandal proof panel door

Remote custom annunicator

EMCP 4.3 , EMCP 4.2B

Local discrete I/O package

Common alarm/shutdown relay

Ground fault relay

Generator running VFC

Cooling System

Radiator duct flange

Jacket water heaters

European Certifications

Eurasian Conformity (EAC) mark

Exhaust System

Through wall installation kit

Mufflers

Manifold and turbocharger guards

Elbow kit

Generator and Attachments

Permanent magnet excitation (PMG)

Space heater

Digital voltage regulator

Lube System

Manual sump pump

Mounting System

Fuel tank base (1200 ltr)

Starting / Charging

Oversize batteries

Battery chargers

Battery disconnect switch

Heavy duty starting system

Governing System

Electronic Governor (ADEM™ A5)

    Send an Enquiry