Specifications
-
Standard/Optional Equipment
- Catalog
Standby Rating
3100(no fan)/3000 kVA
Prime Power Rating
2825(no fan)/2725 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
380 to 11000 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
3100 kVA
Minimum Rating
2500 kVA
Engine Model
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.89in
Stroke
8.66in
Displacement
5166.88in³
Compression Ratio
16.7:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Governor Type
ADEM� A4
Length - Minimum
251.9in
Length - Maximum
320.2in
Width - Minimum
82.7in
Width - Maximum
109.1in
Height - Minimum
86.9in
Height - Maximum
130.1in
Dry Weight - Genset (minimum)
42750lb
Dry Weight - Genset (maximum)
50750lb
Air Inlet System
Single element air cleaner
Dual element air cleaner
Air inlet adapters
Air inlet protection
Control Panel
EMCP 4.4
EMCP 4.4 optional harness
Controller and MV&HV power connection locations
Load share module
Controller mounting location - LV / MV
Customer AC-DC connection mounting location - LV/MV
Load share module / auxiliary plate and auxiliary box (LV)
Load share governor
Frame boxes
Automatically selected ground
Controller voltage and current sensing groups
Raise lower switch
Speed adjust
Annunciator modules
Customer interface options
Generator temperature monitoring
Modbus monitoring of packages
E-Stop
Interconnect harness
Generator harness
Cooling System
Package mounted radiator
Remote radiators
Fuel cooler
Exhaust System
Front housing - Standby or mission critical
Front housing - Prime or continuous
Exhaust collectors/manifold
Exhaust support group
Mufflers
Weld flanges
Aftercooler drain
Crankcase Systems
Explosive relief valves
Crankcase ventilation system
Fuel System
Primary fuel filter
Generators and Attachments
Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
Space heater kit
Thermostat for space heater
Conversion GP - Top cable entry
Generator air intake
Differential current transformers
Instrumentation
Pyrometer and thermocouples
Lube System
Lube oil heater
Drain group oil pans
Lubricating oil
Electric prelube pumps
Oil filters
Mounting
Rubber anti-vibration mounts
Spring type linear vibration isolators
IBC vibration isolators - Shipped loose
Power Connections
Center post busbarss (LV)
Side/rear mounted busbars (LV)
Harnesses (Breaker)
Cable entry options (LV)
Enclosures - Control packaging (LV)
Power connection covers (LV)
Neutral ground (LV)
1800 Frame generators Circuit breaker
Masterpack breakers
Paralleling circuit breakers
1800 Frame generator side / rear mounted busbars (MV)
Cable entry options (MV)
Neutral ground (MV)
Low voltage connection cable
Masterpack breaker connections
Special Tests / Reports
Generator test report
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Standard genset TVA (Torsional Vibration Analysis) report
Custom generator TVA report
Special test charge - Engine only
Genset fuel consumption test
Standard engine test charge
IBC seismic Certification
OSCOSH1 seismic Certification
Starting / Charging System
24 Volt power distribution box
24 Volt electric starting motor
Air starting motor
Air pressure regulator
Starter location covers
24 Volt battery set - Dry
Heavy duty battery sets with rack
20 Amp Battery chargers
35 Amp Battery chargers
50 Amp Battery chargers
Charging alternators - Dry
Jacket water heaters
Jacket water heater wiring groups
General
Special paint colors
Service tools - Engine barring group
Barring group manual
Engine barring air powered
Control GP - air powered bar group
Air Inlet System
4 x Single element canister with service indicator(s)
Control Panel
Cat ECS 100
Volts (L-L & L-N)
Engine cycle crank
Power factor (per phase & average)
Overcurrent
Communications
Emergency stop
2 Programmable relay outputs (Form C)
6 Programmable digital inputs
2 Programmable digital outputs
Environmental sealed front face.
DC Volts
Reverse power
Programmable protective relaying functions
High coolant temperature
Accessory module data link
Low coolant level
Over/under frequency
Amps (per phase & average)
True RMS AC metering, 3-phase, +/-2% accuracy
Low coolant temperature
Reverse reactive power
Controls
Oil pressure (psi, kPa or bar)
Lamp test
Coolant temperature
Warning/shutdown Indicators:
4 Programmable relay outputs (Form A)
Alarm acknowledge
Generator phase sequence
24 Volt DC operation
Serial annunciator module data link
Customer data link (Modbus RTU)
Failure to start (overcrank)
Auto/start/stop control.
Low oil pressure
RPM
Text alarm/event descriptions.
Digital Indicators
Generator mounted - rear facing
Emergency stop pushbutton
Engine cool-down timer
Operating hours
Over/under voltage
Overspeed
Frequency (Hz)
Cooling System
Radiator group - shipped loose
SCAC cooling
Coolant Sensors
Coolant drain line and valves
Fan and belt guards
Exhaust System
Bolted flange, with bellow for each turbo
Dry exhaust manifold
Fuel System
Filters x 3
Secondary/ tertiary fuel filters
10 Micron spin On Type
4 Micron Spin On Type
Primary fuel filter water/fuel water separator
Engine mounted filters x 3
Generator and Attachments
6 Leads
IEC platinum stator RTDs
Voltage regulator
Reactive droop capability
3 Phase voltage sensing
RFI suppression
Min / max exciter limiter
exciter diode monitor
Form wound
Permanent magnet excitation (PMG)
NEMA Class H insulation
Class H temperature rise at 40C ambient
(LV) Busbar connections, top/center mounted, top cable entry
3 Phase Brushless
Salient pole
50 Hz models: IEC standard hole pattern
(MV) Busbar connections, right side extension box, bottom cable entry
Anti-condensation space heater
Class F temperature rise at 40C ambient
Right side extension box, bottom cable entry
Governing System
ADEM A4
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
Lube System
Gear type lube oil pump
Lubricating oil
Fumes disposal
Integral lube Oil cooler
Oil drain lines and valve
Oil filter, filler and dipstick
Prelube - required with prime, continuous, and standby
Mounting Systems
Rubber anti-vibration mounts - shipped loose
Battery disconnect switch
Batteries and battery rack w/cables
Dual 24 volt electric starting motors
Rails - Engine/generator
Service Instructions
Two PM inspections
Power Termination
Busbar
General
Paint - Caterpillar yellow with high gloss black rails & radiator
Right hand servicing
Flywheel and flywheel housing-SAE No. 00
SAE standard rotation
ALL
Air Inlet System
4 x Single element canister with service indicator(s)
Control Panel
Cat ECS 100
Volts (L-L & L-N)
Engine cycle crank
Power factor (per phase & average)
Overcurrent
Communications
Emergency stop
2 Programmable relay outputs (Form C)
6 Programmable digital inputs
2 Programmable digital outputs
Environmental sealed front face.
DC Volts
Reverse power
Programmable protective relaying functions
High coolant temperature
Accessory module data link
Low coolant level
Over/under frequency
Amps (per phase & average)
True RMS AC metering, 3-phase, +/-2% accuracy
Low coolant temperature
Reverse reactive power
Controls
Oil pressure (psi, kPa or bar)
Lamp test
Coolant temperature
Warning/shutdown Indicators:
4 Programmable relay outputs (Form A)
Alarm acknowledge
Generator phase sequence
24 Volt DC operation
Serial annunciator module data link
Customer data link (Modbus RTU)
Failure to start (overcrank)
Auto/start/stop control.
Low oil pressure
RPM
Text alarm/event descriptions.
Digital Indicators
Generator mounted - rear facing
Emergency stop pushbutton
Engine cool-down timer
Operating hours
Over/under voltage
Overspeed
Frequency (Hz)
Cooling System
Radiator group - shipped loose
SCAC cooling
Coolant Sensors
Coolant drain line and valves
Fan and belt guards
Exhaust System
Bolted flange, with bellow for each turbo
Dry exhaust manifold
Fuel System
Filters x 3
Secondary/ tertiary fuel filters
10 Micron spin On Type
4 Micron Spin On Type
Primary fuel filter water/fuel water separator
Engine mounted filters x 3
Generator and Attachments
6 Leads
IEC platinum stator RTDs
Voltage regulator
Reactive droop capability
3 Phase voltage sensing
RFI suppression
Min / max exciter limiter
exciter diode monitor
Form wound
Permanent magnet excitation (PMG)
NEMA Class H insulation
Class H temperature rise at 40C ambient
(LV) Busbar connections, top/center mounted, top cable entry
3 Phase Brushless
Salient pole
50 Hz models: IEC standard hole pattern
(MV) Busbar connections, right side extension box, bottom cable entry
Anti-condensation space heater
Class F temperature rise at 40C ambient
Right side extension box, bottom cable entry
Governing System
ADEM A4
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
Lube System
Gear type lube oil pump
Lubricating oil
Fumes disposal
Integral lube Oil cooler
Oil drain lines and valve
Oil filter, filler and dipstick
Prelube - required with prime, continuous, and standby
Mounting Systems
Rubber anti-vibration mounts - shipped loose
Battery disconnect switch
Batteries and battery rack w/cables
Dual 24 volt electric starting motors
Rails - Engine/generator
Service Instructions
Two PM inspections
Power Termination
Busbar
General
Paint - Caterpillar yellow with high gloss black rails & radiator
Right hand servicing
Flywheel and flywheel housing-SAE No. 00
SAE standard rotation
Optional Equipment
Air Inlet System
Single element air cleaner
Dual element air cleaner
Air inlet adapters
Air inlet protection
Control Panel
EMCP 4.4
EMCP 4.4 optional harness
Controller and MV&HV power connection locations
Load share module
Controller mounting location - LV / MV
Customer AC-DC connection mounting location - LV/MV
Load share module / auxiliary plate and auxiliary box (LV)
Load share governor
Frame boxes
Automatically selected ground
Controller voltage and current sensing groups
Raise lower switch
Speed adjust
Annunciator modules
Customer interface options
Generator temperature monitoring
Modbus monitoring of packages
E-Stop
Interconnect harness
Generator harness
Cooling System
Package mounted radiator
Remote radiators
Fuel cooler
Exhaust System
Front housing - Standby or mission critical
Front housing - Prime or continuous
Exhaust collectors/manifold
Exhaust support group
Mufflers
Weld flanges
Aftercooler drain
Crankcase Systems
Explosive relief valves
Crankcase ventilation system
Fuel System
Primary fuel filter
Generators and Attachments
Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
Space heater kit
Thermostat for space heater
Conversion GP - Top cable entry
Generator air intake
Differential current transformers
Instrumentation
Pyrometer and thermocouples
Lube System
Lube oil heater
Drain group oil pans
Lubricating oil
Electric prelube pumps
Oil filters
Mounting
Rubber anti-vibration mounts
Spring type linear vibration isolators
IBC vibration isolators - Shipped loose
Power Connections
Center post busbarss (LV)
Side/rear mounted busbars (LV)
Harnesses (Breaker)
Cable entry options (LV)
Enclosures - Control packaging (LV)
Power connection covers (LV)
Neutral ground (LV)
1800 Frame generators Circuit breaker
Masterpack breakers
Paralleling circuit breakers
1800 Frame generator side / rear mounted busbars (MV)
Cable entry options (MV)
Neutral ground (MV)
Low voltage connection cable
Masterpack breaker connections
Special Tests / Reports
Generator test report
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Standard genset TVA (Torsional Vibration Analysis) report
Custom generator TVA report
Special test charge - Engine only
Genset fuel consumption test
Standard engine test charge
IBC seismic Certification
OSCOSH1 seismic Certification
Starting / Charging System
24 Volt power distribution box
24 Volt electric starting motor
Air starting motor
Air pressure regulator
Starter location covers
24 Volt battery set - Dry
Heavy duty battery sets with rack
20 Amp Battery chargers
35 Amp Battery chargers
50 Amp Battery chargers
Charging alternators - Dry
Jacket water heaters
Jacket water heater wiring groups
General
Special paint colors
Service tools - Engine barring group
Barring group manual
Engine barring air powered
Control GP - air powered bar group