402

C175-16 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Standby Rating

3100(no fan)/3000 kVA

Prime Power Rating

2825(no fan)/2725 kVA

Emissions/Fuel Strategy

Low Fuel, Low Emissions

Voltage

380 to 11000 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby, Mission Critical, Prime, Continuous

Maximum Rating

3100 kVA

Minimum Rating

2500 kVA

Engine Model

C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel

Bore

6.89in

Stroke

8.66in

Displacement

5166.88in³

Compression Ratio

16.7:1

Aspiration

Turbo Aftercooled

Fuel System

Common Rail

Governor Type

ADEM� A4

Length - Minimum

251.9in

Length - Maximum

320.2in

Width - Minimum

82.7in

Width - Maximum

109.1in

Height - Minimum

86.9in

Height - Maximum

130.1in

Dry Weight - Genset (minimum)

42750lb

Dry Weight - Genset (maximum)

50750lb

Air Inlet System

Single element air cleaner

Dual element air cleaner

Air inlet adapters

Air inlet protection

Control Panel

EMCP 4.4

EMCP 4.4 optional harness

Controller and MV&HV power connection locations

Load share module

Controller mounting location - LV / MV

Customer AC-DC connection mounting location - LV/MV

Load share module / auxiliary plate and auxiliary box (LV)

Load share governor

Frame boxes

Automatically selected ground

Controller voltage and current sensing groups

Raise lower switch

Speed adjust

Annunciator modules

Customer interface options

Generator temperature monitoring

Modbus monitoring of packages

E-Stop

Interconnect harness

Generator harness

Cooling System

Package mounted radiator

Remote radiators

Fuel cooler

Exhaust System

Front housing - Standby or mission critical

Front housing - Prime or continuous

Exhaust collectors/manifold

Exhaust support group

Mufflers

Weld flanges

Aftercooler drain

Crankcase Systems

Explosive relief valves

Crankcase ventilation system

Fuel System

Primary fuel filter

Generators and Attachments

Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667

Space heater kit

Thermostat for space heater

Conversion GP - Top cable entry

Generator air intake

Differential current transformers

Instrumentation

Pyrometer and thermocouples

Lube System

Lube oil heater

Drain group oil pans

Lubricating oil

Electric prelube pumps

Oil filters

Mounting

Rubber anti-vibration mounts

Spring type linear vibration isolators

IBC vibration isolators - Shipped loose

Power Connections

Center post busbarss (LV)

Side/rear mounted busbars (LV)

Harnesses (Breaker)

Cable entry options (LV)

Enclosures - Control packaging (LV)

Power connection covers (LV)

Neutral ground (LV)

1800 Frame generators Circuit breaker

Masterpack breakers

Paralleling circuit breakers

1800 Frame generator side / rear mounted busbars (MV)

Cable entry options (MV)

Neutral ground (MV)

Low voltage connection cable

Masterpack breaker connections

Special Tests / Reports

Generator test report

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Standard genset TVA (Torsional Vibration Analysis) report

Custom generator TVA report

Special test charge - Engine only

Genset fuel consumption test

Standard engine test charge

IBC seismic Certification

OSCOSH1 seismic Certification

Starting / Charging System

24 Volt power distribution box

24 Volt electric starting motor

Air starting motor

Air pressure regulator

Starter location covers

24 Volt battery set - Dry

Heavy duty battery sets with rack

20 Amp Battery chargers

35 Amp Battery chargers

50 Amp Battery chargers

Charging alternators - Dry

Jacket water heaters

Jacket water heater wiring groups

General

Special paint colors

Service tools - Engine barring group

Barring group manual

Engine barring air powered

Control GP - air powered bar group

Air Inlet System

4 x Single element canister with service indicator(s)

Control Panel

Cat ECS 100

Volts (L-L & L-N)

Engine cycle crank

Power factor (per phase & average)

Overcurrent

Communications

Emergency stop

2 Programmable relay outputs (Form C)

6 Programmable digital inputs

2 Programmable digital outputs

Environmental sealed front face.

DC Volts

Reverse power

Programmable protective relaying functions

High coolant temperature

Accessory module data link

Low coolant level

Over/under frequency

Amps (per phase & average)

True RMS AC metering, 3-phase, +/-2% accuracy

Low coolant temperature

Reverse reactive power

Controls

Oil pressure (psi, kPa or bar)

Lamp test

Coolant temperature

Warning/shutdown Indicators:

4 Programmable relay outputs (Form A)

Alarm acknowledge

Generator phase sequence

24 Volt DC operation

Serial annunciator module data link

Customer data link (Modbus RTU)

Failure to start (overcrank)

Auto/start/stop control.

Low oil pressure

RPM

Text alarm/event descriptions.

Digital Indicators

Generator mounted - rear facing

Emergency stop pushbutton

Engine cool-down timer

Operating hours

Over/under voltage

Overspeed

Frequency (Hz)

Cooling System

Radiator group - shipped loose

SCAC cooling

Coolant Sensors

Coolant drain line and valves

Fan and belt guards

Exhaust System

Bolted flange, with bellow for each turbo

Dry exhaust manifold

Fuel System

Filters x 3

Secondary/ tertiary fuel filters

10 Micron spin On Type

4 Micron Spin On Type

Primary fuel filter water/fuel water separator

Engine mounted filters x 3

Generator and Attachments

6 Leads

IEC platinum stator RTDs

Voltage regulator

Reactive droop capability

3 Phase voltage sensing

RFI suppression

Min / max exciter limiter

exciter diode monitor

Form wound

Permanent magnet excitation (PMG)

NEMA Class H insulation

Class H temperature rise at 40C ambient

(LV) Busbar connections, top/center mounted, top cable entry

3 Phase Brushless

Salient pole

50 Hz models: IEC standard hole pattern

(MV) Busbar connections, right side extension box, bottom cable entry

Anti-condensation space heater

Class F temperature rise at 40C ambient

Right side extension box, bottom cable entry

Governing System

ADEM A4

Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

Gear type lube oil pump

Lubricating oil

Fumes disposal

Integral lube Oil cooler

Oil drain lines and valve

Oil filter, filler and dipstick

Prelube - required with prime, continuous, and standby

Mounting Systems

Rubber anti-vibration mounts - shipped loose

Battery disconnect switch

Batteries and battery rack w/cables

Dual 24 volt electric starting motors

Rails - Engine/generator

Service Instructions

Two PM inspections

Power Termination

Busbar

General

Paint - Caterpillar yellow with high gloss black rails & radiator

Right hand servicing

Flywheel and flywheel housing-SAE No. 00

SAE standard rotation

ALL

Air Inlet System

4 x Single element canister with service indicator(s)

Control Panel

Cat ECS 100

Volts (L-L & L-N)

Engine cycle crank

Power factor (per phase & average)

Overcurrent

Communications

Emergency stop

2 Programmable relay outputs (Form C)

6 Programmable digital inputs

2 Programmable digital outputs

Environmental sealed front face.

DC Volts

Reverse power

Programmable protective relaying functions

High coolant temperature

Accessory module data link

Low coolant level

Over/under frequency

Amps (per phase & average)

True RMS AC metering, 3-phase, +/-2% accuracy

Low coolant temperature

Reverse reactive power

Controls

Oil pressure (psi, kPa or bar)

Lamp test

Coolant temperature

Warning/shutdown Indicators:

4 Programmable relay outputs (Form A)

Alarm acknowledge

Generator phase sequence

24 Volt DC operation

Serial annunciator module data link

Customer data link (Modbus RTU)

Failure to start (overcrank)

Auto/start/stop control.

Low oil pressure

RPM

Text alarm/event descriptions.

Digital Indicators

Generator mounted - rear facing

Emergency stop pushbutton

Engine cool-down timer

Operating hours

Over/under voltage

Overspeed

Frequency (Hz)

Cooling System

Radiator group - shipped loose

SCAC cooling

Coolant Sensors

Coolant drain line and valves

Fan and belt guards

Exhaust System

Bolted flange, with bellow for each turbo

Dry exhaust manifold

Fuel System

Filters x 3

Secondary/ tertiary fuel filters

10 Micron spin On Type

4 Micron Spin On Type

Primary fuel filter water/fuel water separator

Engine mounted filters x 3

Generator and Attachments

6 Leads

IEC platinum stator RTDs

Voltage regulator

Reactive droop capability

3 Phase voltage sensing

RFI suppression

Min / max exciter limiter

exciter diode monitor

Form wound

Permanent magnet excitation (PMG)

NEMA Class H insulation

Class H temperature rise at 40C ambient

(LV) Busbar connections, top/center mounted, top cable entry

3 Phase Brushless

Salient pole

50 Hz models: IEC standard hole pattern

(MV) Busbar connections, right side extension box, bottom cable entry

Anti-condensation space heater

Class F temperature rise at 40C ambient

Right side extension box, bottom cable entry

Governing System

ADEM A4

Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

Gear type lube oil pump

Lubricating oil

Fumes disposal

Integral lube Oil cooler

Oil drain lines and valve

Oil filter, filler and dipstick

Prelube - required with prime, continuous, and standby

Mounting Systems

Rubber anti-vibration mounts - shipped loose

Battery disconnect switch

Batteries and battery rack w/cables

Dual 24 volt electric starting motors

Rails - Engine/generator

Service Instructions

Two PM inspections

Power Termination

Busbar

General

Paint - Caterpillar yellow with high gloss black rails & radiator

Right hand servicing

Flywheel and flywheel housing-SAE No. 00

SAE standard rotation

Optional Equipment

Air Inlet System

Single element air cleaner

Dual element air cleaner

Air inlet adapters

Air inlet protection

Control Panel

EMCP 4.4

EMCP 4.4 optional harness

Controller and MV&HV power connection locations

Load share module

Controller mounting location - LV / MV

Customer AC-DC connection mounting location - LV/MV

Load share module / auxiliary plate and auxiliary box (LV)

Load share governor

Frame boxes

Automatically selected ground

Controller voltage and current sensing groups

Raise lower switch

Speed adjust

Annunciator modules

Customer interface options

Generator temperature monitoring

Modbus monitoring of packages

E-Stop

Interconnect harness

Generator harness

Cooling System

Package mounted radiator

Remote radiators

Fuel cooler

Exhaust System

Front housing - Standby or mission critical

Front housing - Prime or continuous

Exhaust collectors/manifold

Exhaust support group

Mufflers

Weld flanges

Aftercooler drain

Crankcase Systems

Explosive relief valves

Crankcase ventilation system

Fuel System

Primary fuel filter

Generators and Attachments

Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667

Space heater kit

Thermostat for space heater

Conversion GP - Top cable entry

Generator air intake

Differential current transformers

Instrumentation

Pyrometer and thermocouples

Lube System

Lube oil heater

Drain group oil pans

Lubricating oil

Electric prelube pumps

Oil filters

Mounting

Rubber anti-vibration mounts

Spring type linear vibration isolators

IBC vibration isolators - Shipped loose

Power Connections

Center post busbarss (LV)

Side/rear mounted busbars (LV)

Harnesses (Breaker)

Cable entry options (LV)

Enclosures - Control packaging (LV)

Power connection covers (LV)

Neutral ground (LV)

1800 Frame generators Circuit breaker

Masterpack breakers

Paralleling circuit breakers

1800 Frame generator side / rear mounted busbars (MV)

Cable entry options (MV)

Neutral ground (MV)

Low voltage connection cable

Masterpack breaker connections

Special Tests / Reports

Generator test report

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Standard genset TVA (Torsional Vibration Analysis) report

Custom generator TVA report

Special test charge - Engine only

Genset fuel consumption test

Standard engine test charge

IBC seismic Certification

OSCOSH1 seismic Certification

Starting / Charging System

24 Volt power distribution box

24 Volt electric starting motor

Air starting motor

Air pressure regulator

Starter location covers

24 Volt battery set - Dry

Heavy duty battery sets with rack

20 Amp Battery chargers

35 Amp Battery chargers

50 Amp Battery chargers

Charging alternators - Dry

Jacket water heaters

Jacket water heater wiring groups

General

Special paint colors

Service tools - Engine barring group

Barring group manual

Engine barring air powered

Control GP - air powered bar group