-
Specifications
-
Standard/Optional Equipment
- Catalog
Standby Rating
4000(no fan)/3900 kVA
Prime Power Rating
3600(no fan)/3500 kVA
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Voltage
400 to 11000 Volts
Frequency
50 Hz
Speed
1500 RPM
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Maximum Rating
4000 kVA
Minimum Rating
3150 kVA
Engine Model
C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Bore
6.89in
Stroke
8.66in
Displacement
6456.31in³
Compression Ratio
15.3:1
Aspiration
Turbo Aftercooled
Fuel System
Common Rail
Governor Type
ADEM� A4
Length - Minimum
264.2in
Length - Maximum
330.8in
Width - Minimum
85.1in
Width - Maximum
127.8in
Height - Minimum
87.6in
Height - Maximum
150.7in
Dry Weight - Genset (minimum)
55100lb
Dry Weight - Genset (maximum)
66200lb
Air Inlet Systems
Single element air cleaner
Control Panels
EMCP 4.4
Controller and MV and HV power connection locations
Load share module
Controller voltage and current sensing groups
Speed adjust
Annunciator modules
Customer interface options
Generator temperature monitoring
E-Stop
Interconnect harness
Generator harness
Modbus monitoring of packages
Vandal proof panel door
Cooling System
Package mounted radiators
Remote radiators
Fuel cooler
Crankcase Systems
Explosive relief valves
Crankcase ventilation system
Exhaust System
Front housing - Standby or mission critical
Front housing - Prime or continuous
Exhaust collectors/manifold
Mufflers (15, 25 and 34 dBA)
Fuel System
Primary fuel filter
Generators and Attachments
Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Thermostat for space heater
Generator air cleaner
Differential current transformers - (5, 9 and 15 kV Class)
Instrumentation
Pyrometer and thermocouples
Lube System
Lube oil heater
Lube oil heater with Crankcase explosion relief valves
Drain group oil pans
Lubricating oil
Electric prelube pumps
Oil filters
Mounting System
Rubber anti-vibration mounts
Spring type linear vibration isolators
IBC vibration isolators - Shipped loose
Special Tests / Reports
Generator test report
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Standard genset TVA (Torsional Vibration Analysis) report
Custom generator TVA report
Special test charge - Engine only
Genset fuel consumption test
Standard engine test charge
Starting / Charging System
24 Volt electric starting motor
Air starting motor
Air pressure regulator
Starter location covers
24 Volt battery set - Dry
20, 35 and 50 Amp Battery chargers
Charging alternators - Dry
Jacket water heaters
General
Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
US aid emblem
Service tools
Engine barring group
Manual
Engine barring air powered
control GP - air powered bar group
Air Inlet
4 x Single element canister air cleaners with service indicator(s).
Control Panel
Engine cycle crank
Oil pressure (psi, kPa or bar)
Digital Indicators
Coolant temperature
Environmental sealed front face
Frequency (Hz)
True RMS AC metering, 3-phase, +/-2% accuracy
Text alarm/event descriptions
Low coolant level
Volts (L-L & L-N)
Auto/start/stop control
Warning/shutdown Indicators:
Emergency stop pushbutton
Engine cool-down timer
DC volts
High coolant temperature
Operating hours
Low oil pressure
Cat ECS 100
Amps (per phase & average)
4 Programmable relay Inputs
Alarm acknowledge
4 Programmable relay output
Failure to start (overcrank)
Overspeed
Lamp test
24 Volt DC operation
Wall mounted controls
RPM
Cooling System
SCAC cooling
Coolant sensors
JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
Exhaust
Dry exhaust manifold
Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz
Fuel
Filters x 3
Secondary/tertiary fuel filters
4 Micron spin on type
10 Micron spin on type
Engine mounted filters x 3
Primary fuel filter water/fuel water separator
Generators and Attachments
Salient pole
RFI suppression
Anti-condensation space heater
IEC platinum Stator RTDs
Form wound
NEMA Class H insulation
Voltage regulator
Reactive droop capability
Min/max Exciter limiter
3 Phase voltage sensing
Exciter diode monitor
6 Leads
3 Phase brushless
Right side extension box, bottom cable entry
Permanent magnet excitation (PMG)
Class H temperature rise at 40C ambient
Governing System
ADEM A4
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
Lube System
Oil drain lines and valve
Gear type lube oil pump
Oil filter, filler and dipstick
Integral lube Oil cooler
Lubricating oil
Fumes disposal
Mounting Systems
Rails - Engine/Generator
Rubber anti-vibration mounts - shipped loose
Starting / Charging System
Batteries and battery rack w/cables
Dual 24 volt electric starting motors
Battery disconnect switch
General
SAE standard rotation
Right hand servicing
Paint - Caterpillar yellow with high gloss black rails
ALL
Air Inlet
4 x Single element canister air cleaners with service indicator(s).
Control Panel
Engine cycle crank
Oil pressure (psi, kPa or bar)
Digital Indicators
Coolant temperature
Environmental sealed front face
Frequency (Hz)
True RMS AC metering, 3-phase, +/-2% accuracy
Text alarm/event descriptions
Low coolant level
Volts (L-L & L-N)
Auto/start/stop control
Warning/shutdown Indicators:
Emergency stop pushbutton
Engine cool-down timer
DC volts
High coolant temperature
Operating hours
Low oil pressure
Cat ECS 100
Amps (per phase & average)
4 Programmable relay Inputs
Alarm acknowledge
4 Programmable relay output
Failure to start (overcrank)
Overspeed
Lamp test
24 Volt DC operation
Wall mounted controls
RPM
Cooling System
SCAC cooling
Coolant sensors
JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
Exhaust
Dry exhaust manifold
Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz
Fuel
Filters x 3
Secondary/tertiary fuel filters
4 Micron spin on type
10 Micron spin on type
Engine mounted filters x 3
Primary fuel filter water/fuel water separator
Generators and Attachments
Salient pole
RFI suppression
Anti-condensation space heater
IEC platinum Stator RTDs
Form wound
NEMA Class H insulation
Voltage regulator
Reactive droop capability
Min/max Exciter limiter
3 Phase voltage sensing
Exciter diode monitor
6 Leads
3 Phase brushless
Right side extension box, bottom cable entry
Permanent magnet excitation (PMG)
Class H temperature rise at 40C ambient
Governing System
ADEM A4
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
Lube System
Oil drain lines and valve
Gear type lube oil pump
Oil filter, filler and dipstick
Integral lube Oil cooler
Lubricating oil
Fumes disposal
Mounting Systems
Rails - Engine/Generator
Rubber anti-vibration mounts - shipped loose
Starting / Charging System
Batteries and battery rack w/cables
Dual 24 volt electric starting motors
Battery disconnect switch
General
SAE standard rotation
Right hand servicing
Paint - Caterpillar yellow with high gloss black rails
Optional Equipment
Air Inlet Systems
Single element air cleaner
Control Panels
EMCP 4.4
Controller and MV and HV power connection locations
Load share module
Controller voltage and current sensing groups
Speed adjust
Annunciator modules
Customer interface options
Generator temperature monitoring
E-Stop
Interconnect harness
Generator harness
Modbus monitoring of packages
Vandal proof panel door
Cooling System
Package mounted radiators
Remote radiators
Fuel cooler
Crankcase Systems
Explosive relief valves
Crankcase ventilation system
Exhaust System
Front housing - Standby or mission critical
Front housing - Prime or continuous
Exhaust collectors/manifold
Mufflers (15, 25 and 34 dBA)
Fuel System
Primary fuel filter
Generators and Attachments
Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
Thermostat for space heater
Generator air cleaner
Differential current transformers - (5, 9 and 15 kV Class)
Instrumentation
Pyrometer and thermocouples
Lube System
Lube oil heater
Lube oil heater with Crankcase explosion relief valves
Drain group oil pans
Lubricating oil
Electric prelube pumps
Oil filters
Mounting System
Rubber anti-vibration mounts
Spring type linear vibration isolators
IBC vibration isolators - Shipped loose
Special Tests / Reports
Generator test report
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8 power factor
Standard genset TVA (Torsional Vibration Analysis) report
Custom generator TVA report
Special test charge - Engine only
Genset fuel consumption test
Standard engine test charge
Starting / Charging System
24 Volt electric starting motor
Air starting motor
Air pressure regulator
Starter location covers
24 Volt battery set - Dry
20, 35 and 50 Amp Battery chargers
Charging alternators - Dry
Jacket water heaters
General
Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
US aid emblem
Service tools
Engine barring group
Manual
Engine barring air powered
control GP - air powered bar group