Specifications
-
Standard/Optional Equipment
- Catalog
Frequency
60 Hz
Natural Gas Rating
230 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Speed
1800 rpm
Aspiration
Turbocharged - Aftercooled
Governor Type
Electronic
Bore
1463.1mm
Stroke
1728.3mm
Length
2887kg
Width
57.6in
Height
68.04in
Weight
6364lb
Starting/Charging
Battery heater
Charging alternator
Jacket water heater
Battery charger – UL Listed 10 amp
General
Suitable for Use as Service Equipment (SUSE)
Automatic transfer switches (ATS)
CSA Certification
Enclosures: sound attenuated, weather protective
UL 2200 package
Generator
Anti-condensation heater
Shunt trip and auxiliary contact breaker
Thermal magnetic or electronic trip MCCBs
Excitation: [ ] Permanent Magnet Excited (PM)
Anti-condensation heater
Oversize and premium generators
Cooling
Factory-installed radiator
Closed coolant recovery system
50/50 Ethylene glycol antifreeze
Radiator and cooling fan complete with protective guards
Standard ambient temperatures up to 50°C (122°F)
Air Inlet
Single element air filter
Fuel
Low fuel pressure switch
Primary and secondary fuel shut-off
Fuel pressure test po
Dual lock off valves
Natural Gas or LP Vapor
NPT connection
Generator
Class H insulation material
Full load capacity alternator
Permanent magnet excitation
Class H insulation material
Full load capacity alternator
Integrated Voltage Regulator
Matched to the performance and output characteristics of Cat engines
Permanent magnet excitation
IP23 Protection
Exhaust
Exhaust outlet with 3” pipe
Controls
EMCP 4.2 Series generator set controller
Mounting
Vibration isolaton (puck type)
Rubber vibration isolators
Electric Power - Package Serial Number Prefix
Battery charging alternator
Electric Starting and/or Prelube
Battery cables
Engine electrical system
Solenoid activated starter motor
Solenoid activated starter motor
Governor
Electronic governor (non adjustable)
Control Panel
EMCP 4.2 Series generator set controller
Starting/Charging
Batteries with rack and cables
12 volt starting motor
ALL
Cooling
Factory-installed radiator
Closed coolant recovery system
50/50 Ethylene glycol antifreeze
Radiator and cooling fan complete with protective guards
Standard ambient temperatures up to 50°C (122°F)
Air Inlet
Single element air filter
Fuel
Low fuel pressure switch
Primary and secondary fuel shut-off
Fuel pressure test po
Dual lock off valves
Natural Gas or LP Vapor
NPT connection
Generator
Class H insulation material
Full load capacity alternator
Permanent magnet excitation
Class H insulation material
Full load capacity alternator
Integrated Voltage Regulator
Matched to the performance and output characteristics of Cat engines
Permanent magnet excitation
IP23 Protection
Exhaust
Exhaust outlet with 3” pipe
Controls
EMCP 4.2 Series generator set controller
Mounting
Vibration isolaton (puck type)
Rubber vibration isolators
Electric Power - Package Serial Number Prefix
Battery charging alternator
Electric Starting and/or Prelube
Battery cables
Engine electrical system
Solenoid activated starter motor
Solenoid activated starter motor
Governor
Electronic governor (non adjustable)
Control Panel
EMCP 4.2 Series generator set controller
Starting/Charging
Batteries with rack and cables
12 volt starting motor
Optional Equipment
Starting/Charging
Battery heater
Charging alternator
Jacket water heater
Battery charger – UL Listed 10 amp
General
Suitable for Use as Service Equipment (SUSE)
Automatic transfer switches (ATS)
CSA Certification
Enclosures: sound attenuated, weather protective
UL 2200 package
Generator
Anti-condensation heater
Shunt trip and auxiliary contact breaker
Thermal magnetic or electronic trip MCCBs
Excitation: [ ] Permanent Magnet Excited (PM)
Anti-condensation heater
Oversize and premium generators