Specifications
-
Standard/Optional Equipment
- Catalog
Gas Standby Rating
750 ekW @ 0.8pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset
RPM
1800 rpm
Frequency
60 Hz
Displacement
3173in³
Engine Model
G3512
Displacement
3173in³
Aspiration
TA
Bore
6.7in
Stroke
7.5in
Length
205.7in
Width
90in
Height
99.4in
Weight
27500lb
Governor Type
ADEM A4
Air Inlet
Mounting brackets and piping
Air cleaner with precleaner
Circuit Breakers
S LSI, G LSIG, P LSIG-P, 4th Digit Type
Right, left, rear mounted
1200A, 3 Pole, UL-100% Rated P-Frame Circuit Breakers
1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
2000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
3-pole (IEC 947-2 rated)
Frame mounting
Control Panel
Remote annunciator
Local alarm module
Local PC monitoring
Engine failure relay
Remote PC monitoring
Cooling
Coolant level drain line with valves, fan with guard
Remote radiator for JW and SCAC circuits, level switch included but not wired
Inlet/Outlet connections
Exhaust
305 mm (12in.) elbow
18, 25 dBA Attenuation
Flexible fittings
305 mm (12 in.) muffler
305mm (12 in) spark arresting muffler
305 mm (12 in.) flange
Fuel System
3, 0-100 kPag, 4-20mA gas train pressure sensors
General
Special paint order
US AID emblem
Tool set
Digital diagnostic tool
Generator
Cable access box
Generator air filter
European bus bars
Low voltage extension box
Bearing temperature detectors
Starting/Charging
20A, 24VDC battery charger
Battery with cables and rack
Jacket water heater
45A, 24V charging alternator (requires engine driven pumps)
Grid Code Compliance
60 Hz: USA
Air Inlet
Dual air cleaners, 1 per side, with service indicator
Two-element single-stage air cleaner with enclosure and service indicator
Control Panel
Cat ECS 100
Cooling
Engine driven pumps for jacket water and separate circuit aftercooler
Jacket water and SCAC engine-driven pumps
Jacket water and SCAC thermostats
LH or RG connections when radiator is not selected
Package mounted radiator
Fuel
NOx sensor based air-fuel-ratio control
0.5 to 5 psi engine fuel inlet pressure
Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number
Gas Train: NFPA37 and CSA B149.3
Exhaust
Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
Dry exhaust manifolds, insulated and shielded
Cat-flanged face outlet on turbocharger
Fuel System
Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
Throttle plate, 24V DC actuator, controlled by GECM
Engine-installed electronic control valve
Gas pressure regulator
24V DC energized-to-run (ETR) gas shutoff valve
General
Crankshaft vibration damper and guard
Operation and maintenance manuals
Parts book
Paint- Caterpillar Yellow except rails and radiators gloss black
RH Service
Lubrication
Gear type lube oil pump
Cartridge style oil filter
Generator
Anti-condensation space heater
Winding temperature detectors
NEMA Class H insulation
SR5
Permanent Magnet Excitiation
Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter
Governing System
ADEM A4
Ignition System
Individual Cylinder Detonation Sensitive Timing (DST)
Electronic Ignition System (controlled by ADEM A4)
Governing
ADEM A4 speed governor with 4 to 20ma (0V to 5V) speed input
Starting/Charging
24V DC starting motors
Batteries with rack and cables
Electric Starter
ALL
Air Inlet
Dual air cleaners, 1 per side, with service indicator
Two-element single-stage air cleaner with enclosure and service indicator
Control Panel
Cat ECS 100
Cooling
Engine driven pumps for jacket water and separate circuit aftercooler
Jacket water and SCAC engine-driven pumps
Jacket water and SCAC thermostats
LH or RG connections when radiator is not selected
Package mounted radiator
Fuel
NOx sensor based air-fuel-ratio control
0.5 to 5 psi engine fuel inlet pressure
Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number
Gas Train: NFPA37 and CSA B149.3
Exhaust
Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
Dry exhaust manifolds, insulated and shielded
Cat-flanged face outlet on turbocharger
Fuel System
Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
Throttle plate, 24V DC actuator, controlled by GECM
Engine-installed electronic control valve
Gas pressure regulator
24V DC energized-to-run (ETR) gas shutoff valve
General
Crankshaft vibration damper and guard
Operation and maintenance manuals
Parts book
Paint- Caterpillar Yellow except rails and radiators gloss black
RH Service
Lubrication
Gear type lube oil pump
Cartridge style oil filter
Generator
Anti-condensation space heater
Winding temperature detectors
NEMA Class H insulation
SR5
Permanent Magnet Excitiation
Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter
Governing System
ADEM A4
Ignition System
Individual Cylinder Detonation Sensitive Timing (DST)
Electronic Ignition System (controlled by ADEM A4)
Governing
ADEM A4 speed governor with 4 to 20ma (0V to 5V) speed input
Starting/Charging
24V DC starting motors
Batteries with rack and cables
Electric Starter
Optional Equipment
Air Inlet
Mounting brackets and piping
Air cleaner with precleaner
Circuit Breakers
S LSI, G LSIG, P LSIG-P, 4th Digit Type
Right, left, rear mounted
1200A, 3 Pole, UL-100% Rated P-Frame Circuit Breakers
1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
2000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers
100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
3-pole (IEC 947-2 rated)
Frame mounting
Control Panel
Remote annunciator
Local alarm module
Local PC monitoring
Engine failure relay
Remote PC monitoring
Cooling
Coolant level drain line with valves, fan with guard
Remote radiator for JW and SCAC circuits, level switch included but not wired
Inlet/Outlet connections
Exhaust
305 mm (12in.) elbow
18, 25 dBA Attenuation
Flexible fittings
305 mm (12 in.) muffler
305mm (12 in) spark arresting muffler
305 mm (12 in.) flange
Fuel System
3, 0-100 kPag, 4-20mA gas train pressure sensors
General
Special paint order
US AID emblem
Tool set
Digital diagnostic tool
Generator
Cable access box
Generator air filter
European bus bars
Low voltage extension box
Bearing temperature detectors
Starting/Charging
20A, 24VDC battery charger
Battery with cables and rack
Jacket water heater
45A, 24V charging alternator (requires engine driven pumps)
Grid Code Compliance
60 Hz: USA