-
Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
600 ekW
Minimum Rating
455 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.71in
Stroke
7.2in
Displacement
1106.4l
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Adem™A4
Length - Maximum
5550in
Width - Maximum
80.9in
Height - Maximum
107.8in
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Generator
Oversize and premium generators
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Anti-condensation heater
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Circuit breakers
3 Pole (IEC-100% rated) Circuit breakers - Motorised
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Shunt trip for IEC breaker
Power terminal strip
Circuit breaker (IEC) Auxiliary contacts
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Padlockable circuit breaker device
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Control Panels
Remote monitoring software
Load share module
Local & remote annunciator modules
GCCP 1.2, GCCP 1.5
Digital I/O module
Control System
Local alarm modules
Volt free contact
Local alarm horn
Remote annunciator module
Oil temperature displays
Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
GCCP 1.5
Cooling System
Low coolant temperature alarm
Radiator duct flange
Enclosures
Sound attenuated enclosures
Starting/Charging
Jacket water heater
Battery chargers
Heavy duty starting system
Oversize batteries
Charging alternator
Exhaust System
8 and 10 inch GP flanges
8 and 10 inch elbow kits
Engine mounted muffler
10, 25 and 35 end in / end out mufflers
Manifold and turbocharger guards
Fuel System
Manual fuel transfer pump
Fuel transfer system
Integral - Dual wall fuel tank base
General
Sound attenuated, weather protective or high ambient weather protective enclosure
Integral & sub-base UL listed dual wall fuel tanks
CSA Certification
Automatic transfer switches (ATS)
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
EU Certificate of Conformance (CE)
EEC Declaration of Conformity
UL 2200 package
Single or dual wall integral fuel tanks
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Narrow, wide or skid base
Enclosures: Sound attenuated, weather protective
Generator and Attachments
Space heaters
A Frame CIP generator
Permanent magnet excitation (PMG)
LC frame generator
A Frame oversize generator
Ingress protection
LC frame CIP generator
LC frame oversize generators
Lube System
Manual sump pump
Starting and Charging
Battery disconnect switch
Jacket water heaters
5 Amp Battery charger
Air Inlet
Air cleaner
Air Inlet System
Turbocharger
Light duty air cleaner
Aftercooler core
Cooling
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
Coolant drain line with valve
Radiator and cooling fan with guard
Package mounted radiator
Exhaust
Exhaust flange outlet
Exhaust System
Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard 8 hour open set fuel tank
Fuel
Secondary fuel filters
Fuel priming pump
Primary fuel filter with integral water separator
Generator and Attachments
Matched to the performance and output characteristics of Cat engines
Segregated low voltage (AC/DC) wiring panel
Power center, IP22
A Frame generator - IP21 protection
Integrated voltage regulator (IVR)
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
Busbar
Control System
GCCP 1.2
Governing System
Cat electronic governor (ADEM A4)
Control Panel
EMCP 4 Genset controller
Lube System
Lubricating oil
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
Mounting
Rubber vibration isolators
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre-paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
ALL
Air Inlet
Air cleaner
Air Inlet System
Turbocharger
Light duty air cleaner
Aftercooler core
Cooling
Caterpillar extended life coolant
Fan drive, battery charging alternator drive
Coolant drain line with valve
Radiator and cooling fan with guard
Package mounted radiator
Exhaust
Exhaust flange outlet
Exhaust System
Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard 8 hour open set fuel tank
Fuel
Secondary fuel filters
Fuel priming pump
Primary fuel filter with integral water separator
Generator and Attachments
Matched to the performance and output characteristics of Cat engines
Segregated low voltage (AC/DC) wiring panel
Power center, IP22
A Frame generator - IP21 protection
Integrated voltage regulator (IVR)
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Integrated voltage regulator (IVR)
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
Busbar
Control System
GCCP 1.2
Governing System
Cat electronic governor (ADEM A4)
Control Panel
EMCP 4 Genset controller
Lube System
Lubricating oil
Oil drain valves
Mounting System
Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
Mounting
Rubber vibration isolators
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre-paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
Air Inlet System
Single element air cleaner
Dual element air cleaner
Exhaust
Industrial, residential, critical mufflers
Generator
Oversize and premium generators
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Anti-condensation heater
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Circuit breakers
3 Pole (IEC-100% rated) Circuit breakers - Motorised
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Shunt trip for IEC breaker
Power terminal strip
Circuit breaker (IEC) Auxiliary contacts
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Padlockable circuit breaker device
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
Control Panels
Remote monitoring software
Load share module
Local & remote annunciator modules
GCCP 1.2, GCCP 1.5
Digital I/O module
Control System
Local alarm modules
Volt free contact
Local alarm horn
Remote annunciator module
Oil temperature displays
Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
GCCP 1.5
Cooling System
Low coolant temperature alarm
Radiator duct flange
Enclosures
Sound attenuated enclosures
Starting/Charging
Jacket water heater
Battery chargers
Heavy duty starting system
Oversize batteries
Charging alternator
Exhaust System
8 and 10 inch GP flanges
8 and 10 inch elbow kits
Engine mounted muffler
10, 25 and 35 end in / end out mufflers
Manifold and turbocharger guards
Fuel System
Manual fuel transfer pump
Fuel transfer system
Integral - Dual wall fuel tank base
General
Sound attenuated, weather protective or high ambient weather protective enclosure
Integral & sub-base UL listed dual wall fuel tanks
CSA Certification
Automatic transfer switches (ATS)
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
EU Certificate of Conformance (CE)
EEC Declaration of Conformity
UL 2200 package
Single or dual wall integral fuel tanks
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Narrow, wide or skid base
Enclosures: Sound attenuated, weather protective
Generator and Attachments
Space heaters
A Frame CIP generator
Permanent magnet excitation (PMG)
LC frame generator
A Frame oversize generator
Ingress protection
LC frame CIP generator
LC frame oversize generators
Lube System
Manual sump pump
Starting and Charging
Battery disconnect switch
Jacket water heaters
5 Amp Battery charger