402

C18 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

715 kVA

Minimum Rating

550 kVA

Emissions/Fuel Strategy

Low Fuel, EU Stage IIIA

Voltage

380 to 415 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby, Prime

Engine Model

C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

Bore

5.71in

Stroke

7.2in

Displacement

1106.4in³

Compression Ratio

14.5:1

Aspiration

Air to Air Aftercooled

Fuel System

Electronic unit injection

Governor Type

Adem™A4

Length - Minimum

218.5in

Length - Maximum

218.5in

Width - Maximum

80.9in

Height - Maximum

107.8in

Certifications

Global

European Certifications - EU Certificate of Conformance (CE)

Exhaust

Industrial, residential, critical mufflers

Air Inlet System

Dual element air cleaner

Single element air cleaner

Generator

Oversize and premium generators

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Anti-condensation heater

Power Termination

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Circuit breakers

4 Pole (IEC-100% rated) - package mounted

3 Pole (IEC-100% rated) - package mounted

Padlockable device

4 Pole (IEC-100% rated) - motorized

Power terminal strip

3 Pole (IEC-100% rated) - motorized

Control Panel

GCCP 1.4

Control Panels

Local & remote annunciator modules

Digital I/O module

Load share module

EMCP (4.2) (4.3) (4.4)

Remote monitoring software

Control System

Local alarm modules

Control panel protective devices

Remote annunciator module

Volt free contacts

Cooling System

Radiator duct flange

Enclosures

Sound attenuated enclosures

Starting/Charging

Heavy duty starting system

Battery chargers

Charging alternator

Oversize batteries

Jacket water heater

Exhaust System

Elbow Kit

Mufflers - End in/end out

Manifold and turbocharger guards

Engine mounted muffler

Flange groups; 8 and 10 inch weld flanges and gaskets

Fuel System

Integral dual wall fuel tank base

Manual fuel transfer system

Fuel transfer system

General

Integral & sub-base UL listed dual wall fuel tanks

UL 2200 package

Narrow, wide or skid base

Enclosures: Sound attenuated, weather protective

Sound attenuated, weather protective or high ambient weather protective enclosure

EEC Declaration of Conformity

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

The following options are based on regional and product configuration:

Single or dual wall sub-base fuel tanks

Automatic transfer switches (ATS)

CSA Certification

EU Certificate of Conformance (CE)

Single or dual wall integral fuel tanks

Generator and Attachments

A Frame CIP generator

LC frame generator

Permanent magnet excitation (PMG)

LC frame oversize generator

Space heaters

Ingress protection

LC frame CIP generator

A Frame oversize generator

Lube System

Manual sump pump

Mounting System

Narrow skid base

Starting / Charging System

5 Amp Battery charger

Jacket water heater

Battery disconnect switch

Air System

Air cleaner, light duty

Turborcharger

Air Inlet

Air cleaner

Control Panel

GCCP 1.3

GCCP Genset Controller

Cooling

Package mounted radiator

Cooling System

Coolant drain line with valve

Fan drive, battery charging alternator drive

Radiator and cooling fan with guard

Caterpillar extended life coolant

Exhaust

Exhaust flange outlet

Exhaust System

Stainless steel exhaust flex, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

Standard open set fuel tank/base supplied Base, formed steel with single wall integral 8-hour fuel tank

Fuel

Fuel priming pump

Secondary fuel filters

Primary fuel filter with integral water separator

Generator

Matched to the performance and output characteristics of Cat engines

IP23 Protection

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Generator and Attachments

Segregated low voltage (AC/DC) wiring panel

Power center, IP22

Optional LC Frame generator - IP23 Protection,

Mandatory option rear circuit breaker, IEC, 3 pole, mounted in power center

Integrated voltage regulator (IVR)

A Frame generator - IP21 Protection

Governing System

Cat electronic governor (ADEM A4)

Power Termination

Busbar

Lube System

Oil drain valves

Lubricating oil

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting / Charging

24 Volt battery with rack and cables

Starting/Charging

24 volt starting motor

Batteries

Mounting

Rubber vibration isolators

General

Engine and alternator pre-paint, Caterpillar yellow

Paint - Caterpillar yellow except rails and radiators gloss black

ALL

Air System

Air cleaner, light duty

Turborcharger

Air Inlet

Air cleaner

Control Panel

GCCP 1.3

GCCP Genset Controller

Cooling

Package mounted radiator

Cooling System

Coolant drain line with valve

Fan drive, battery charging alternator drive

Radiator and cooling fan with guard

Caterpillar extended life coolant

Exhaust

Exhaust flange outlet

Exhaust System

Stainless steel exhaust flex, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

Standard open set fuel tank/base supplied Base, formed steel with single wall integral 8-hour fuel tank

Fuel

Fuel priming pump

Secondary fuel filters

Primary fuel filter with integral water separator

Generator

Matched to the performance and output characteristics of Cat engines

IP23 Protection

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Generator and Attachments

Segregated low voltage (AC/DC) wiring panel

Power center, IP22

Optional LC Frame generator - IP23 Protection,

Mandatory option rear circuit breaker, IEC, 3 pole, mounted in power center

Integrated voltage regulator (IVR)

A Frame generator - IP21 Protection

Governing System

Cat electronic governor (ADEM A4)

Power Termination

Busbar

Lube System

Oil drain valves

Lubricating oil

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting / Charging

24 Volt battery with rack and cables

Starting/Charging

24 volt starting motor

Batteries

Mounting

Rubber vibration isolators

General

Engine and alternator pre-paint, Caterpillar yellow

Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

Certifications

Global

European Certifications - EU Certificate of Conformance (CE)

Exhaust

Industrial, residential, critical mufflers

Air Inlet System

Dual element air cleaner

Single element air cleaner

Generator

Oversize and premium generators

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Anti-condensation heater

Power Termination

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Circuit breakers

4 Pole (IEC-100% rated) - package mounted

3 Pole (IEC-100% rated) - package mounted

Padlockable device

4 Pole (IEC-100% rated) - motorized

Power terminal strip

3 Pole (IEC-100% rated) - motorized

Control Panel

GCCP 1.4

Control Panels

Local & remote annunciator modules

Digital I/O module

Load share module

EMCP (4.2) (4.3) (4.4)

Remote monitoring software

Control System

Local alarm modules

Control panel protective devices

Remote annunciator module

Volt free contacts

Cooling System

Radiator duct flange

Enclosures

Sound attenuated enclosures

Starting/Charging

Heavy duty starting system

Battery chargers

Charging alternator

Oversize batteries

Jacket water heater

Exhaust System

Elbow Kit

Mufflers - End in/end out

Manifold and turbocharger guards

Engine mounted muffler

Flange groups; 8 and 10 inch weld flanges and gaskets

Fuel System

Integral dual wall fuel tank base

Manual fuel transfer system

Fuel transfer system

General

Integral & sub-base UL listed dual wall fuel tanks

UL 2200 package

Narrow, wide or skid base

Enclosures: Sound attenuated, weather protective

Sound attenuated, weather protective or high ambient weather protective enclosure

EEC Declaration of Conformity

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

The following options are based on regional and product configuration:

Single or dual wall sub-base fuel tanks

Automatic transfer switches (ATS)

CSA Certification

EU Certificate of Conformance (CE)

Single or dual wall integral fuel tanks

Generator and Attachments

A Frame CIP generator

LC frame generator

Permanent magnet excitation (PMG)

LC frame oversize generator

Space heaters

Ingress protection

LC frame CIP generator

A Frame oversize generator

Lube System

Manual sump pump

Mounting System

Narrow skid base

Starting / Charging System

5 Amp Battery charger

Jacket water heater

Battery disconnect switch

    Send an Enquiry