Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
600 ekW
Minimum Rating
455 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
5.71in
Stroke
7.2in
Displacement
1106.4in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Adem™A4
Length - Maximum
218.5in
Width - Maximum
80.9in
Height - Maximum
107.8in
Air Inlet System
Dual element air cleaner
Single element air cleaner
Exhaust
Industrial, residential, critical mufflers
Circuit breakers
3 Pole (IEC-100% rated) Circuit breakers - Motorised
Power terminal strip
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Shunt trip for IEC breaker
Padlockable circuit breaker device
Circuit breaker (IEC) Auxiliary contacts
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Generator
Anti-condensation heater
Oversize and premium generators
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Control Panels
Load share module
Local & remote annunciator modules
GCCP 1.2, GCCP 1.5
Remote monitoring software
Digital I/O module
Control System
Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
Local alarm modules
Local alarm horn
Oil temperature displays
GCCP 1.5
Volt free contact
Remote annunciator module
Starting/Charging
Heavy duty starting system
Battery chargers
Jacket water heater
Charging alternator
Oversize batteries
Cooling System
Low coolant temperature alarm
Radiator duct flange
Enclosures
Sound attenuated enclosures
Exhaust System
Engine mounted muffler
8 and 10 inch GP flanges
10, 25 and 35 end in / end out mufflers
Manifold and turbocharger guards
8 and 10 inch elbow kits
Fuel System
Manual fuel transfer pump
Integral - Dual wall fuel tank base
Fuel transfer system
General
CSA Certification
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Integral & sub-base UL listed dual wall fuel tanks
Narrow, wide or skid base
Single or dual wall integral fuel tanks
Automatic transfer switches (ATS)
UL 2200 package
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
EEC Declaration of Conformity
Sound attenuated, weather protective or high ambient weather protective enclosure
Enclosures: Sound attenuated, weather protective
EU Certificate of Conformance (CE)
Generator and Attachments
Ingress protection
Permanent magnet excitation (PMG)
A Frame CIP generator
LC frame generator
LC frame oversize generators
A Frame oversize generator
LC frame CIP generator
Space heaters
Lube System
Manual sump pump
Starting and Charging
Jacket water heaters
5 Amp Battery charger
Battery disconnect switch
Air Inlet
Air cleaner
Air Inlet System
Light duty air cleaner
Turbocharger
Aftercooler core
Governing System
Cat electronic governor (ADEM A4)
Control System
GCCP 1.2
Cooling
Radiator and cooling fan with guard
Fan drive, battery charging alternator drive
Coolant drain line with valve
Caterpillar extended life coolant
Package mounted radiator
Exhaust
Exhaust flange outlet
Exhaust System
Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel
Fuel priming pump
Secondary fuel filters
Primary fuel filter with integral water separator
Fuel System
Standard 8 hour open set fuel tank
Generator and Attachments
Matched to the performance and output characteristics of Cat engines
Integrated voltage regulator (IVR)
Segregated low voltage (AC/DC) wiring panel
A Frame generator - IP21 protection
Integrated voltage regulator (IVR)
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Power center, IP22
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
Busbar
Control Panel
GCCP Genset Controller
Lube System
Lubricating oil
Oil drain valves
Mounting
Rubber vibration isolators
Mounting System
Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre-paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
ALL
Air Inlet
Air cleaner
Air Inlet System
Light duty air cleaner
Turbocharger
Aftercooler core
Governing System
Cat electronic governor (ADEM A4)
Control System
GCCP 1.2
Cooling
Radiator and cooling fan with guard
Fan drive, battery charging alternator drive
Coolant drain line with valve
Caterpillar extended life coolant
Package mounted radiator
Exhaust
Exhaust flange outlet
Exhaust System
Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel
Fuel priming pump
Secondary fuel filters
Primary fuel filter with integral water separator
Fuel System
Standard 8 hour open set fuel tank
Generator and Attachments
Matched to the performance and output characteristics of Cat engines
Integrated voltage regulator (IVR)
Segregated low voltage (AC/DC) wiring panel
A Frame generator - IP21 protection
Integrated voltage regulator (IVR)
Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Power center, IP22
Generator
IP23 Protection
Matched to the performance and output characteristics of Cat engines
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
Busbar
Control Panel
GCCP Genset Controller
Lube System
Lubricating oil
Oil drain valves
Mounting
Rubber vibration isolators
Mounting System
Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
24 Volt battery with rack and cables
24 volt starting motor
Batteries
General
Engine and alternator pre-paint, Caterpillar yellow
Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
Air Inlet System
Dual element air cleaner
Single element air cleaner
Exhaust
Industrial, residential, critical mufflers
Circuit breakers
3 Pole (IEC-100% rated) Circuit breakers - Motorised
Power terminal strip
3 Pole (IEC-100% rated) Circuit breakers - Package mounted
Shunt trip for IEC breaker
Padlockable circuit breaker device
Circuit breaker (IEC) Auxiliary contacts
4 Pole (IEC-100% rated) Circuit breakers - Package mounted
4 Pole (IEC-100% rated) Circuit breakers - Motorised
Generator
Anti-condensation heater
Oversize and premium generators
Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Power Termination
Circuit breakers, UL listed
Circuit breakers, IEC compliant
Control Panels
Load share module
Local & remote annunciator modules
GCCP 1.2, GCCP 1.5
Remote monitoring software
Digital I/O module
Control System
Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
Local alarm modules
Local alarm horn
Oil temperature displays
GCCP 1.5
Volt free contact
Remote annunciator module
Starting/Charging
Heavy duty starting system
Battery chargers
Jacket water heater
Charging alternator
Oversize batteries
Cooling System
Low coolant temperature alarm
Radiator duct flange
Enclosures
Sound attenuated enclosures
Exhaust System
Engine mounted muffler
8 and 10 inch GP flanges
10, 25 and 35 end in / end out mufflers
Manifold and turbocharger guards
8 and 10 inch elbow kits
Fuel System
Manual fuel transfer pump
Integral - Dual wall fuel tank base
Fuel transfer system
General
CSA Certification
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Integral & sub-base UL listed dual wall fuel tanks
Narrow, wide or skid base
Single or dual wall integral fuel tanks
Automatic transfer switches (ATS)
UL 2200 package
The following options are based on regional and product configuration:
Single or dual wall sub-base fuel tanks
EEC Declaration of Conformity
Sound attenuated, weather protective or high ambient weather protective enclosure
Enclosures: Sound attenuated, weather protective
EU Certificate of Conformance (CE)
Generator and Attachments
Ingress protection
Permanent magnet excitation (PMG)
A Frame CIP generator
LC frame generator
LC frame oversize generators
A Frame oversize generator
LC frame CIP generator
Space heaters
Lube System
Manual sump pump
Starting and Charging
Jacket water heaters
5 Amp Battery charger
Battery disconnect switch