Standby Rating

3500/3250/3000 kVA

Prime Power Rating

3175/2950/2725 kVA

Emissions/Fuel Strategy

U.S. EPA Cert. Tier 2 / Low NOx

Voltage

380 to 11000 volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby, Mission Critical, Prime

Maximum Rating

3500 kVA

Minimum Rating

2725 kVA

Engine Model

3516E, V-16, 4-Stroke Water-Cooled Diesel

Bore

6.69in

Stroke

8.46in

Displacement

4765in³

Compression Ratio

14.0:1

Aspiration

ATAAC

Fuel System

Electronic Unit Injection

Governor Type

Adem™ A5

Length - Minimum

313.4in

Length - Maximum

318.4in

Width - Minimum

104in

Width - Maximum

104in

Height - Minimum

131.6in

Height - Maximum

131.6in

Dry Weight - Genset (minimum)

44930lb

Dry Weight - Genset (maximum)

45651lb

Control System

EMCP 4.4

Air Inlet System

Single element filter

Dual element air cleaner

Cooling System

Standard ambient ATAAC radiators

Water level switch gauges

Optional installed ATAAC radiators

Coolant

Optional installed radiators

Standard ambient radiators

Crankcase System

Ventilation system

Explosion relief valves

No explosion relief valves

Exhaust System

Y Adapters

Fuel System

Primary fuel filter

Fuel priming pumps (Tier 4) - Manual or electric

General

US aid emblem

Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

Thermostat for space heater

Alternator air cleaner

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Generator conversion

Space heater

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Instrumentation

Pyrometer and thermocouples

Lubrication System

Lube oil in standard sump

Prelube pumps

Oil level regulator

Mounting System

Puck style low efficiency isolators

Spring type vibration isolators

IBC vibration isolators

Power Connections

Neutral ground connections

Center post busbars

Right side power connections

Special Tests / Reports

Generator set fuel consumption test

Torsional vibration analysis reports

PGS Test report @ 0.8 power factor

IBC Certification

PGS Test report @ 1.0 power factor

Canadian Standards Association certification

Standard engine test charge

Generator test report

Fuel consumption test

OSHPD Certification

Starting and Charging

Air pressure regulator

Jacket water heaters

Air starting motors

24 Volt battery set - Dry

Starter cover

Engine barring device

10, 20, 35 and 50 Amp Battery chargers

Electric starting motors

Extended Service Coverage

Platinum, Gold and Silver coverage

Air Inlet System

Air cleaner; single element canister type

Control System

Generator set packages include:

Emergency stop pushbutton

24 Volt DC operation

KVAR / PF modes

IVR includes reactive droop capability

Cat ECS 100

Text alarm/event descriptions

Generator mounted - rear facing

Environmental sealed front face

RFI suppression

3 Phase voltage sensing

Caterpillar's voltage regulator

Min / max exciter

Limiter and exciter diode monitor

Controls:

Speed adjust

Auto/start/stop control

Engine cycle crank

Engine cool

Alarm acknowledge

PLC functionality

Customizable screens

Lamp test

Load histogram feature

Generator phase sequence

1 Programmable relay outputs (Form C)

RPM

High coolant temperature

Accessory module data link

Low coolant level

Number of I/O varies on options selected

Digital indication for:

Reverse power (kW) (32)

Reverse reactive power (kVAr) (32RV)

Overcurrent (50/51)

6 Customer programmable digital inputs

3 Analog inputs

Serial annunciator module data link

Over/under frequency (81 o/u)

Low coolant temperature

+/- 2% accuracy

Programmable protective relaying functions:

Failure to start (overcrank)

4 Programmable relay outputs (Form A)

Cat connect

Over/under voltage (27/59)

1 Programmable digital outputs

0 True RMS AC metering

3 Phase

Communications:

Overspeed

DC volts

Operating hours

Coolant temperature

Oil pressure (psi, kPa or bar)

Volts (L-L & L-N)

Power factor (per phase & average)

Frequency (Hz)

Amps (per phase & average)

kW (per phase, average & percent)

kVA (per phase, average & percent)

kVAr (per phase, average & percent)

Low oil pressure

kVAr-hr (total)

kW-hr (total)

Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -

Cooling System

ATAAC - 3516E package radiators shipped installed

Certified standard PGS provided

Exhaust System

Dry exhaust manifold

Flanged faced outlet(s)

Fuel System

Fuel cooler; not included with packages without radiator

Secondary fuel filters

Flexible fuel lines - shipped loose

General

SAE standard rotation

Flywheel and flywheel housing - SAE No. 00

Right hand servicing

Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

Anti-condensation space heater

Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern

3 Phase brushless, Salient pole

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Winding temperature detectors

High voltage:

Medium voltage:

Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)

NEMA standard hole pattern

6 Lead

Permanent magnet excitation (PMG)

Form wound

Busbar connections, right side extension box, bottom cable entry

Governing System

ADEM A5

Literature

Parts book

Operation & Maintenance Manual

Lubrication System

Gear type lube oil pump

Lubricating oil

Oil filter, filler and dipstick

Integral lube oil cool

Oil drain lines and valve

Fumes disposal

Mounting System

Rails - Engine/generator/radiator mounting

Anti-vibration mounts (shipped loose)

Rubber anti-vibration mounts - shipped loose

Starting System

24 Volt electric starting motor

45 Amp Charging alternator

Battery and battery rack w/cables

Battery disconnect switch

ALL

Air Inlet System

Air cleaner; single element canister type

Control System

Generator set packages include:

Emergency stop pushbutton

24 Volt DC operation

KVAR / PF modes

IVR includes reactive droop capability

Cat ECS 100

Text alarm/event descriptions

Generator mounted - rear facing

Environmental sealed front face

RFI suppression

3 Phase voltage sensing

Caterpillar's voltage regulator

Min / max exciter

Limiter and exciter diode monitor

Controls:

Speed adjust

Auto/start/stop control

Engine cycle crank

Engine cool

Alarm acknowledge

PLC functionality

Customizable screens

Lamp test

Load histogram feature

Generator phase sequence

1 Programmable relay outputs (Form C)

RPM

High coolant temperature

Accessory module data link

Low coolant level

Number of I/O varies on options selected

Digital indication for:

Reverse power (kW) (32)

Reverse reactive power (kVAr) (32RV)

Overcurrent (50/51)

6 Customer programmable digital inputs

3 Analog inputs

Serial annunciator module data link

Over/under frequency (81 o/u)

Low coolant temperature

+/- 2% accuracy

Programmable protective relaying functions:

Failure to start (overcrank)

4 Programmable relay outputs (Form A)

Cat connect

Over/under voltage (27/59)

1 Programmable digital outputs

0 True RMS AC metering

3 Phase

Communications:

Overspeed

DC volts

Operating hours

Coolant temperature

Oil pressure (psi, kPa or bar)

Volts (L-L & L-N)

Power factor (per phase & average)

Frequency (Hz)

Amps (per phase & average)

kW (per phase, average & percent)

kVA (per phase, average & percent)

kVAr (per phase, average & percent)

Low oil pressure

kVAr-hr (total)

kW-hr (total)

Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -

Cooling System

ATAAC - 3516E package radiators shipped installed

Certified standard PGS provided

Exhaust System

Dry exhaust manifold

Flanged faced outlet(s)

Fuel System

Fuel cooler; not included with packages without radiator

Secondary fuel filters

Flexible fuel lines - shipped loose

General

SAE standard rotation

Flywheel and flywheel housing - SAE No. 00

Right hand servicing

Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

Anti-condensation space heater

Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern

3 Phase brushless, Salient pole

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Winding temperature detectors

High voltage:

Medium voltage:

Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)

NEMA standard hole pattern

6 Lead

Permanent magnet excitation (PMG)

Form wound

Busbar connections, right side extension box, bottom cable entry

Governing System

ADEM A5

Literature

Parts book

Operation & Maintenance Manual

Lubrication System

Gear type lube oil pump

Lubricating oil

Oil filter, filler and dipstick

Integral lube oil cool

Oil drain lines and valve

Fumes disposal

Mounting System

Rails - Engine/generator/radiator mounting

Anti-vibration mounts (shipped loose)

Rubber anti-vibration mounts - shipped loose

Starting System

24 Volt electric starting motor

45 Amp Charging alternator

Battery and battery rack w/cables

Battery disconnect switch

Optional Equipment

Control System

EMCP 4.4

Air Inlet System

Single element filter

Dual element air cleaner

Cooling System

Standard ambient ATAAC radiators

Water level switch gauges

Optional installed ATAAC radiators

Coolant

Optional installed radiators

Standard ambient radiators

Crankcase System

Ventilation system

Explosion relief valves

No explosion relief valves

Exhaust System

Y Adapters

Fuel System

Primary fuel filter

Fuel priming pumps (Tier 4) - Manual or electric

General

US aid emblem

Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

Thermostat for space heater

Alternator air cleaner

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Generator conversion

Space heater

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Instrumentation

Pyrometer and thermocouples

Lubrication System

Lube oil in standard sump

Prelube pumps

Oil level regulator

Mounting System

Puck style low efficiency isolators

Spring type vibration isolators

IBC vibration isolators

Power Connections

Neutral ground connections

Center post busbars

Right side power connections

Special Tests / Reports

Generator set fuel consumption test

Torsional vibration analysis reports

PGS Test report @ 0.8 power factor

IBC Certification

PGS Test report @ 1.0 power factor

Canadian Standards Association certification

Standard engine test charge

Generator test report

Fuel consumption test

OSHPD Certification

Starting and Charging

Air pressure regulator

Jacket water heaters

Air starting motors

24 Volt battery set - Dry

Starter cover

Engine barring device

10, 20, 35 and 50 Amp Battery chargers

Electric starting motors

Extended Service Coverage

Platinum, Gold and Silver coverage

    Send an Enquiry