402

XGC1900

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Rating

1900 ekW (2375 kVA) Continuous

Frequency

50/60 Hz

Voltage

400/480 V

Engine

Cat G3516H

Fuel

Natural Gas

Width - Without Chassis

96in

Height - Without Chassis

114in

Length - Without Chassis

480in

Weight - Without Chassis, With Lube Oil and Coolant

77780lb

Engine

G3516H, V16, 4-stroke-cycle, gas engine. Operates on 24.10 to 93.95 MJ/Nm3 (615 to 2386 btu/ft3) dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled

Generator

Double bearing SR5 1866 Frame, brushless, form wound, 12-lead design, permanent magnet excited, thouree-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters

Containerized Module

40' ISO high cube container, 9-high stack CSC certified. Sound attenuated 79 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and 2lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection

Cooling

Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m

Generator Controls And Protection

On Package EMCP 4.3 Control Panel System Offers engine and generator monitoring and protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFD control, and primary generator protection for greater versatility, package utilization and monitoring.

Modes of Operation

Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control

Lube Oil Make-Up System

Oil pan-mounted oil level regulator and 114 L (30 gal) oil tank Low level annunciation

ALL

Engine

G3516H, V16, 4-stroke-cycle, gas engine. Operates on 24.10 to 93.95 MJ/Nm3 (615 to 2386 btu/ft3) dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled

Generator

Double bearing SR5 1866 Frame, brushless, form wound, 12-lead design, permanent magnet excited, thouree-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters

Containerized Module

40' ISO high cube container, 9-high stack CSC certified. Sound attenuated 79 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and 2lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection

Cooling

Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m

Generator Controls And Protection

On Package EMCP 4.3 Control Panel System Offers engine and generator monitoring and protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFD control, and primary generator protection for greater versatility, package utilization and monitoring.

Modes of Operation

Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control

Lube Oil Make-Up System

Oil pan-mounted oil level regulator and 114 L (30 gal) oil tank Low level annunciation

    Send an Enquiry