Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
60 ekW
Minimum Rating
60 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
269in
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Governor Type
Mechanical, ADEM™A4
Length - Maximum
77.2in
Width - Maximum
43.3in
Height - Maximum
48in
Dry Weight - Genset (maximum)
2054lb
Certificates
IBC seismic and wind Certifications
Alternator System
R Frame auxilliary winding
Air Inlet System
Cartridge type air filter
Charging System
NFPA battery charger UL10A 120VAC
Circuit breakers
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
Control Panels
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Ground fault relay
Remote E-stop button
Volt free contacts genset run and common alarm
Oil temperature gauge and sender
Audible alarm
Remote annunciator module
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Discrete I/O module
Cooling System
Radiator transition flange
Enclosures
Sound attenuated enclosure, Level 1
External emergency stop
Sound attenuated Level 2 Enclosure (White)
Panel viewing window
Exhaust System
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Fuel System
Emergency vent pipe
Tank riser
5 Gallon spill containment
209 and 394 gallon sub-base fuel tanks
5 Gallon fill containment
Heating Elements
Battery heater
Jacket water heater
Coolant heater
Anti-condensation heater
Wiring for canopy space heater
Lube oil sump heater
Generators
Permanent magnet excitation (PMG) generator
Cat Alternator
Mounting System
Seismic vibration isolators
Tests
4 Hour factory test
Generator test report
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor
Certificates
IBC seismic and wind Certifications
Air Inlet System
Air cleaner
Cartridge type air filter
Circuit breakers
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
Charging System
NFPA battery charger UL10A 120VAC
Control Panel
GCCP 1.2 Control panel
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Control Panels
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
WCA1 Low coolant temperature alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
PBC10NU NFPA battery charger
Oil temperature gauge and sender
PAA1 Panel mounted audible alarm
Ground fault relay
Remote E-stop button
Remote annunciator module
Audible alarm
Volt free contacts genset run and common alarm
Discrete I/O module
Overload shutdown via breaker
Low coolant temperature alarm
Protective devices:
Fuel level reading
Low coolant level shutdown
Cooling System
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guards
Radiator stone guard
Generator
12 Leads
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Oil drain line with valve
Lubricating oil
General
Engine and alternator pre-paint, Caterpillar yellow
Starting/Charging System
Batteries
24V battery with rack and cables
ALL
Certificates
IBC seismic and wind Certifications
Air Inlet System
Air cleaner
Cartridge type air filter
Circuit breakers
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
Charging System
NFPA battery charger UL10A 120VAC
Control Panel
GCCP 1.2 Control panel
Exhaust System
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Control Panels
WSS1 Low coolant level shut down
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
NFPA110 bundle includes:
WCA1 Low coolant temperature alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
PBC10NU NFPA battery charger
Oil temperature gauge and sender
PAA1 Panel mounted audible alarm
Ground fault relay
Remote E-stop button
Remote annunciator module
Audible alarm
Volt free contacts genset run and common alarm
Discrete I/O module
Overload shutdown via breaker
Low coolant temperature alarm
Protective devices:
Fuel level reading
Low coolant level shutdown
Cooling System
Coolant drain line with valve
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guards
Radiator stone guard
Generator
12 Leads
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Oil drain line with valve
Lubricating oil
General
Engine and alternator pre-paint, Caterpillar yellow
Starting/Charging System
Batteries
24V battery with rack and cables
Optional Equipment
Certificates
IBC seismic and wind Certifications
Alternator System
R Frame auxilliary winding
Air Inlet System
Cartridge type air filter
Charging System
NFPA battery charger UL10A 120VAC
Circuit breakers
Breakers (100% UL rated)
3-Pole 100% rated
Second circuit breaker box
Power terminal strip
Control Panels
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
Ground fault relay
Remote E-stop button
Volt free contacts genset run and common alarm
Oil temperature gauge and sender
Audible alarm
Remote annunciator module
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Discrete I/O module
Cooling System
Radiator transition flange
Enclosures
Sound attenuated enclosure, Level 1
External emergency stop
Sound attenuated Level 2 Enclosure (White)
Panel viewing window
Exhaust System
10, 25 and 35 dBA silencer systems
Overhead silencer mounting kit
Fuel System
Emergency vent pipe
Tank riser
5 Gallon spill containment
209 and 394 gallon sub-base fuel tanks
5 Gallon fill containment
Heating Elements
Battery heater
Jacket water heater
Coolant heater
Anti-condensation heater
Wiring for canopy space heater
Lube oil sump heater
Generators
Permanent magnet excitation (PMG) generator
Cat Alternator
Mounting System
Seismic vibration isolators
Tests
4 Hour factory test
Generator test report
PGS Test report @ 0.8 power factor
PGS Test report @ 1.0 power factor