402

DE65 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Standby Rating

65 kVA

Frequency

50 Hz

Emissions/Fuel Strategy

Low BSFC

Voltage

380 to 415 Volts

Speed

1500 rpm

Duty Cycle

Standby

Engine Model

Cat® C3.3, In-line 3, 4-cycle diesel

Bore

4.1in

Stroke

5in

Displacement

201.4in³

Compression Ratio

17.25:1

Aspiration

Turbocharged

Fuel System

Inline

Governor Type

Mechanical

Length - Maximum

89.7in

Width - Maximum

35.4in

Height - Maximum

52in

Dry Weight - Genset (maximum)

2273lb

Certification

CE & UKCA

CIS

Alternator Requirements

Space heater

Auxiliary Supply Voltage

120V

Fuel Storage

Single wall tank without containment

Single wall tank with containment

Fuel level alarm

Integral dual wall tank

Low fuel shutdown

Genset Control

Battery charger

Audible alarm

Earth fault

Earth leakage

USB to RS485 Communications device

Emergency stop with key

Battery

Standby Pack (Smart Jacket water heater, Battery charger)

Coolant heater

Low coolant level shutdown

Circuit breaker

3 Pole Circuit breaker 63A

3 Pole Circuit breaker 80A

3 Pole Circuit breaker 100A

3 Pole Circuit breaker 125A

3 Pole Circuit breaker 160A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 80A

4 Pole Circuit breaker 63A

4 Pole Circuit breaker 100A

4 Pole Circuit breaker 125A

4 Pole Circuit breaker 160A

4 Pole Circuit breaker 200A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

Package

Open Set

Engine

C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

GCCP 1.1

Governor

Mechanical governor

Alternator

Standard alternator

Base Type

Skid base

Enclosure

Cat GC enclosure

Air Inlet

Standard air filter

General

Engine and alternator pre-paint, Caterpillar yellow

Telematics

Cat® Product Link™ PL444 cellular

ALL

Engine

C3.3, Inline 3 cylinder, 4 stroke diesel

Genset Control

GCCP 1.1

Governor

Mechanical governor

Alternator

Standard alternator

Base Type

Skid base

Enclosure

Cat GC enclosure

Air Inlet

Standard air filter

General

Engine and alternator pre-paint, Caterpillar yellow

Telematics

Cat® Product Link™ PL444 cellular

Optional Equipment

Certification

CE & UKCA

CIS

Alternator Requirements

Space heater

Auxiliary Supply Voltage

120V

Fuel Storage

Single wall tank without containment

Single wall tank with containment

Fuel level alarm

Integral dual wall tank

Low fuel shutdown

Genset Control

Battery charger

Audible alarm

Earth fault

Earth leakage

USB to RS485 Communications device

Emergency stop with key

Battery

Standby Pack (Smart Jacket water heater, Battery charger)

Coolant heater

Low coolant level shutdown

Circuit breaker

3 Pole Circuit breaker 63A

3 Pole Circuit breaker 80A

3 Pole Circuit breaker 100A

3 Pole Circuit breaker 125A

3 Pole Circuit breaker 160A

3 Pole Circuit breaker 200A

4 Pole Circuit breaker 80A

4 Pole Circuit breaker 63A

4 Pole Circuit breaker 100A

4 Pole Circuit breaker 125A

4 Pole Circuit breaker 160A

4 Pole Circuit breaker 200A

Circuit breaker padlock

Neutral earth link

Overload via alarm switch on breaker

Package

Open Set

    Send an Enquiry