Specifications
-
Standard/Optional Equipment
- Catalog
Maximum Rating
163.9 kVA
Minimum Rating
163.9 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby
Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical
Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
1834lb
Auxiliary Supply Voltage
120V
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Fuel Storage
Dual wall 8 hour fuel tank
High fuel level alarm
Single wall tank with containment
Low fuel level shutdown
Low fuel level alarm
Alternator Requirements
Space heater
Genset Control
Volt free contacts for common alarm
Volt free contacts for genset running
Battery charger
Panel mounted audible alarm
Earth leakage
USB to RS485 Communications device
Earth fault
Emergency stop with key
Coolant heater
Battery
Standby Pack (Smart Jacket water heater, Battery charger)
Low coolant level shutdown
Circuit breaker
4 Pole Circuit breaker 200A
3 Pole Circuit breaker 630A
4 Pole Circuit breaker 250A
3 Pole Circuit breaker 200A
3 Pole Circuit breaker 250A
4 Pole Circuit breaker 630A
4 Pole Circuit breaker 400A
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
3 Pole Circuit breaker 400A
Testing & Packaging
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8PF
Engine
C7.1, Inline 6 cylinder, 4 stroke diesel
Control Panels
GCCP 1.1
Alternator
A Frame standard alternator
Fuel Storage
Single wall 8 hour fuel tank
Governor
Mechanical governor
Enclosure
Cat GC enclosure
Air, Cooling & Exhaust
Enclosure silencer
General
Engine and alternator pre-paint, Caterpillar yellow
ALL
Engine
C7.1, Inline 6 cylinder, 4 stroke diesel
Control Panels
GCCP 1.1
Alternator
A Frame standard alternator
Fuel Storage
Single wall 8 hour fuel tank
Governor
Mechanical governor
Enclosure
Cat GC enclosure
Air, Cooling & Exhaust
Enclosure silencer
General
Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Auxiliary Supply Voltage
120V
Certification
Certificate of Conformance
Australia, CIS, Gulf Certification
Fuel Storage
Dual wall 8 hour fuel tank
High fuel level alarm
Single wall tank with containment
Low fuel level shutdown
Low fuel level alarm
Alternator Requirements
Space heater
Genset Control
Volt free contacts for common alarm
Volt free contacts for genset running
Battery charger
Panel mounted audible alarm
Earth leakage
USB to RS485 Communications device
Earth fault
Emergency stop with key
Coolant heater
Battery
Standby Pack (Smart Jacket water heater, Battery charger)
Low coolant level shutdown
Circuit breaker
4 Pole Circuit breaker 200A
3 Pole Circuit breaker 630A
4 Pole Circuit breaker 250A
3 Pole Circuit breaker 200A
3 Pole Circuit breaker 250A
4 Pole Circuit breaker 630A
4 Pole Circuit breaker 400A
Circuit breaker padlock
Neutral earth link
Overload via alarm switch on breaker
3 Pole Circuit breaker 400A
Testing & Packaging
PGS Test report @ 1.0 power factor
PGS Test report @ 0.8PF