402

DE605 GC (50 Hz) Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Maximum Rating

605 kVA

Minimum Rating

605 kVA

Emissions/Fuel Strategy

Non Regulated

Voltage

380 to 415 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby

Engine Model

C15 In-line 6, 4-cycle diesel

Bore

5.4in

Stroke

6.8in

Displacement

928in³

Compression Ratio

16.1:1

Aspiration

Turbocharged Air-to-Air Aftercooled

Fuel System

EUI

Governor Type

Adem™A4

Length - Maximum

131in

Width - Maximum

60.6in

Height - Maximum

86.1in

Dry Weight - Genset (maximum)

8120lb

Exhaust

Industrial, residential, critical mufflers

Control panel

Speed and Voltage adjust potentiometers

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Enclosure

Cat GC enclosure

Generator

Anti-condensation heater

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Oversize and premium generators

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Alternator

Space heater

AVR

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Manual fuel transfer pump

Fuel transfer system controls

Dual wall fuel tank base

Generator and Attachments

Oversize A Frame generator

LC frame CIP generator

Permanent magnet excitation (PMG) generator

Space heaters

Ingress protection

LC frame generator

A Frame generator - IP21 Protection

CIP A Frame generator

Oversize LC frame generator

Starting/Charging

Charging alternator

Jacket water heater

Battery chargers

Oversize batteries

Heavy duty starting system

24 Volt battery with rack and cables

Air inlet system

Single stage air filter

Dual element air filter

Certifications

EU Certificate of Conformance (CE)

EAC Certification

General

Automatic transfer switches (ATS)

EEC Declaration of Conformity

Integral & sub-base UL listed dual wall fuel tanks

Single or dual wall sub-base fuel tanks

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

CSA Certification

UL 2200 package

The following options are based on regional and product configuration:

Single or dual wall integral fuel tanks

EU Certificate of Conformance (CE)

Sound attenuated, weather protective or high ambient weather protective enclosure

Narrow, wide or skid base

Extended service coverage

3, 4, 5 and 10 Years

Enclosures

High ambient sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Flexible exhaust fittings

6 and 8 inch elbow kit

6 and 8 inch flange GP

Engine mounted muffler

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

5 Amp single Battery charger

Battery disconnect switch

Jacket water heater

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Control Panels

GCCP 1.1

Air Inlet

Air cleaner

Governor

Mechanical governor

Alternator

A Frame standard alternator

Cooling

Package mounted radiator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Caterpillar extended life coolant

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Fuel

Secondary fuel filters

Fuel priming pump

Primary fuel filter with integral water separator

Air inlet system

Air cleaner; light duty with disposable element

Generator

IP23 Protection

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Lube system

Lubricating oil

Oil drain line with valve

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

General

Engine and alternator pre paint, Caterpillar yellow

Engine and alternator pre paint, Caterpillar yellow

Power Termination

Busbar

Generator and Attachments

Power center, IP22

Segregated low voltage (AC/DC) wiring panel

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil cooler

Oil drain valves

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

ALL

Engine

Cat® C15 Inline 6 cylinder, 4 stroke diesel

Control Panels

GCCP 1.1

Air Inlet

Air cleaner

Governor

Mechanical governor

Alternator

A Frame standard alternator

Cooling

Package mounted radiator

Fuel Storage

Single wall 8 hour fuel tank

Cooling System

Caterpillar extended life coolant

Radiator and cooling fan with guards

Fan drive, battery charging alternator drive

Electrical Options

3 Pole Circuit breaker

Neutral earth link

24 Volt battery with rack and cables

Fuel

Secondary fuel filters

Fuel priming pump

Primary fuel filter with integral water separator

Air inlet system

Air cleaner; light duty with disposable element

Generator

IP23 Protection

Matched to the performance and output characteristics of Cat engines

Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Lube system

Lubricating oil

Oil drain line with valve

Mounting system

Captive linear vibration isolators

Lifting provision and drag points

General

Engine and alternator pre paint, Caterpillar yellow

Engine and alternator pre paint, Caterpillar yellow

Power Termination

Busbar

Generator and Attachments

Power center, IP22

Segregated low voltage (AC/DC) wiring panel

Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

Rubber vibration isolators

Governing System

Cat electronic governor (ADEM A4).

Lube System

Oil cooler

Oil drain valves

Mounting System

Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Optional Equipment

Exhaust

Industrial, residential, critical mufflers

Control panel

Speed and Voltage adjust potentiometers

PLG 4G/3G/Ethernet

Annunciator

Emergency E-Stop

Enclosure

Cat GC enclosure

Generator

Anti-condensation heater

Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Oversize and premium generators

Electrical Options

4 Pole Circuit breaker

Auxiliary contacts

Padlockable circuit breaker

Battery charger

Wet battery

Power Termination

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Alternator

Space heater

AVR

Fuel System

Dual wall 8 hour fuel tank

Single wall 8 hour fuel tank with spill containment

Low fuel level shutdown

Low and high fuel level alarms

Manual fuel transfer pump

Fuel transfer system controls

Dual wall fuel tank base

Generator and Attachments

Oversize A Frame generator

LC frame CIP generator

Permanent magnet excitation (PMG) generator

Space heaters

Ingress protection

LC frame generator

A Frame generator - IP21 Protection

CIP A Frame generator

Oversize LC frame generator

Starting/Charging

Charging alternator

Jacket water heater

Battery chargers

Oversize batteries

Heavy duty starting system

24 Volt battery with rack and cables

Air inlet system

Single stage air filter

Dual element air filter

Certifications

EU Certificate of Conformance (CE)

EAC Certification

General

Automatic transfer switches (ATS)

EEC Declaration of Conformity

Integral & sub-base UL listed dual wall fuel tanks

Single or dual wall sub-base fuel tanks

Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

CSA Certification

UL 2200 package

The following options are based on regional and product configuration:

Single or dual wall integral fuel tanks

EU Certificate of Conformance (CE)

Sound attenuated, weather protective or high ambient weather protective enclosure

Narrow, wide or skid base

Extended service coverage

3, 4, 5 and 10 Years

Enclosures

High ambient sound attenuated enclosures

Exhaust System

Industrial silencer

10 dBA Attenuation silencer

Manifold and turbocharger guards

End in/end out mufflers - 10, 25 and 35 dBA attenuation

Flexible exhaust fittings

6 and 8 inch elbow kit

6 and 8 inch flange GP

Engine mounted muffler

Lube System

Manual sump pump

Mounting System

Narrow skid base - replaces standard fuel tank base

Special Test / Reports

PGS Test report @ 1.0 power factor

PGS Test report @ 0.8 power factor

Starting / Charging System

5 Amp single Battery charger

Battery disconnect switch

Jacket water heater

    Send an Enquiry