Specifications
-
Standard/Optional Equipment
- Catalog
Standby Rating
29.6 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
U.S. EPA Tier 4i Certified
Voltage
480/277, 240/120, 208/120, 600/346, 240/120 VAC
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
Cat® C2.2, In-line 4, 4-cycle diesel
Bore
3.3in
Stroke
3.9in
Compression Ratio
23.3:1
Aspiration
Turbocharged air to air charge cooling
Fuel System
Electronically actuated Mechanical Cassette type
Governor Type
Mechanical
Length - Maximum
88.6in
Width - Maximum
41.3in
Height - Maximum
57.9in
Dry Weight - Genset (maximum)
2052lb
Certifications
IBC, UL2200
Alternator and Attachments
PM Excitation
Fault relay, Mounting/Duct plate
Space Heater
Exhaust
Level 2 / Enclosure silencer
Silencer install kit
Power Connection
Shunt trip / Neutral bars
Enclosures
Sound attenuated steel & aluminum
Controls
Remote Annunciator, Panel audible alarm
Input expansion module / NFPA bundle
GFCI, Ground fault relay, E-Stop
Fuel Storage
Fuel level switch and alarm
Fill pipe, Spill containment, Overfill protection
Fuel tank riser / Vent pipe with extension
Integral tank- 24 / 48 / 72 Hrs
Others
Jacket water heater, Battery charger
Engine
Diesel Engine 2.2L, U.S EPA TIER IV Interim
Air Inlet
Standard air cleaner
Exhaust System
Dry exhaust manifold
Base Type
Standard wide skid base
Control Panel and Governing
GCCP 1.2, Mechanical Governor
Telematics
Cat® Product Link™ PL444 cellular
Generators and Generator Attachments
1-Phase and 3-Phase
M-Frame
Starting / Charging System
Starter Motor / Standard Battery
General
Standard Radiator, Turbo and Manifold guards
Paint - Caterpillar yellow except rails are gloss black
Circuit Breakers
Single / Multi LSI
Controls
AVR, Current Transformer
ALL
Engine
Diesel Engine 2.2L, U.S EPA TIER IV Interim
Air Inlet
Standard air cleaner
Exhaust System
Dry exhaust manifold
Base Type
Standard wide skid base
Control Panel and Governing
GCCP 1.2, Mechanical Governor
Telematics
Cat® Product Link™ PL444 cellular
Generators and Generator Attachments
1-Phase and 3-Phase
M-Frame
Starting / Charging System
Starter Motor / Standard Battery
General
Standard Radiator, Turbo and Manifold guards
Paint - Caterpillar yellow except rails are gloss black
Circuit Breakers
Single / Multi LSI
Controls
AVR, Current Transformer
Optional Equipment
Certifications
IBC, UL2200
Alternator and Attachments
PM Excitation
Fault relay, Mounting/Duct plate
Space Heater
Exhaust
Level 2 / Enclosure silencer
Silencer install kit
Power Connection
Shunt trip / Neutral bars
Enclosures
Sound attenuated steel & aluminum
Controls
Remote Annunciator, Panel audible alarm
Input expansion module / NFPA bundle
GFCI, Ground fault relay, E-Stop
Fuel Storage
Fuel level switch and alarm
Fill pipe, Spill containment, Overfill protection
Fuel tank riser / Vent pipe with extension
Integral tank- 24 / 48 / 72 Hrs
Others
Jacket water heater, Battery charger