402

3516B (60 Hz) with Upgradeable Package

The3516B with the upgradeable packaging design has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance to matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Standby Rating

2250 ekW

Prime Power Rating

1825 ekW

Emissions/Fuel Strategy

Low fuel, Low Emissions

Voltage

380 to 480 Volts

Frequency

60 Hz

Speed

1800 rpm

Duty Cycle

Standby, Mission Critical, Prime, Continuous

Maximum Rating

2250 ekW

Minimum Rating

1640 ekW

Engine Model

3516B TA, V-16, 4-Stroke Water-Cooled Diesel

Bore

6.69in

Stroke

7.48in

Displacement

4210.64in

Compression Ratio

14.0:1

Aspiration

TA

Fuel System

MEUI

Governor Type

ADEM™ A4

Length - Maximum

234.5in

Width - Maximum

90in

Height - Maximum

98.2in

Dry Weight - Genset (maximum)

30310lb

Control System

EMCP 4.3, EMCP 4.4

Air Inlet System

Dual element air cleaner

Single element filter

Cooling System

Water level switch gauges

Optional installed ATAAC radiators

Standard ambient ATAAC radiators

Standard ambient radiators

Coolant

Optional installed radiators

Crankcase System

Explosion relief valves

No explosion relief valves

Ventilation system

Exhaust System

Elbows

Flange and exhaust expanders

Tier 4 clean emissions module

Tier 4 clean emission MOD Kits

Clean emission parts

Exhaust offset

Mufflers

Tier 4 dosing cabinet

Flanges

Flexible fittings

Y Adapters

Fuel System

Fuel priming pumps (Tier 4) - Manual or electric

Primary fuel filter

General

US aid emblem

Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Generator conversion

Differential current transformers (DCT)

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Thermostat for space heater

Space heater

High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

Alternator air cleaner

High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

Instrumentation

Pyrometer and Thermocouples

Lubrication System

Oil level regulator

Prelube pumps

Lube oil in standard sump

Mounting System

Puck style low efficiency isolators

Spring type vibration isolators

IBC vibration isolators

Power Connections

Right side power connections

Ground cables between generator and terminal box

Neutral ground connections

Low voltage Circuit breakers

2700 Frame, four lead, four terminal

Rear power connections

Left side power connections

Center post busbars

Special Tests / Reports

PGS Test report @ 0.8 power factor

PGS Test report @ 1.0 power factor

Fuel consumption test

Canadian Standards Association certification

Torsional vibration analysis reports

IBC Certification

Generator test report

Generator set fuel consumption test

OSHPD Certification

Standard engine test charge

Starting and Charging

Engine barring device

Air pressure regulator

Starter cover

Electric starting motors

Jacket water heaters

Air starting motors

24 Volt battery set - Dry

10, 20, 35 and 50 Amp Battery chargers

Extended Service Coverage

Platinum, Gold and Silver coverage

Air Inlet System

Air cleaner; single element canister type

Control Panels

PLC functionality

Oil pressure (psi, kPa or bar)

Text alarm/event descriptions

KVAR/PF modes

Cat connect

Overspeed

Amps (per phase & average)

Programmable protective relaying functions:

DC volts

EMCP 4.2B

Power factor (per phase & average)

Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

Load histogram feature

Generator set packages include:

Frequency (Hz)

Emergency stop pushbutton

Over/under voltage (27/59)

RFI suppression

24 Volt DC operation

Low coolant level

Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

4 Programmable relay outputs (Form A)

Volts (L-L & L-N)

Caterpillar's voltage regulator

IVR includes:

Auto/start/stop control

kVA (per phase, average & percent)

Lamp test

Over/under frequency (81 o/u)

Environmental sealed front face

3 Phase voltage sensing

Engine cool

kVAr-hr (total)

Low oil pressure

Accessory module data link

Emergency stop

Customer data link (Modbus RTU)

Communications:

Warning/shutdown with common LED indication of shutdowns for:

0 True RMS AC metering, 3-phase, +/-2% accuracy

Digital indication for:

Customizable screens

Failure to start (overcrank)

Serial annunciator module data link

Coolant temperature

Controls:

Overcurrent (50/51)

Number of I/O varies on options selected

Reactive droop capability

Low coolant temperature

High coolant temperature

Min / max exciter

Alarm acknowledge

RPM

Generator phase sequence

Limiter and exciter diode monitor

Speed adjust

Operating hours

kW (per phase, average & percent)

3 Analog inputs

Generator mounted - rear facing

6 Customer programmable digital inputs

Lubrication System

Oil filter, filler and dipstick

Oil drain lines and valve

Gear type lube oil pump

Fumes disposal

Lubricating oil

Mounting System

Rubber anti-vibration mounts - shipped loose

Rails - engine/generator/radiator mounting

Anti-vibration mounts (shipped loose)

Starting System

45 Amp Charging alternator

24 Volt electric starting motor

Battery and battery rack w/cables

Battery disconnect switch

Literature

Parts book

Operation & Maintenance Manual

ALL

Air Inlet System

Air cleaner; single element canister type

Control Panels

PLC functionality

Oil pressure (psi, kPa or bar)

Text alarm/event descriptions

KVAR/PF modes

Cat connect

Overspeed

Amps (per phase & average)

Programmable protective relaying functions:

DC volts

EMCP 4.2B

Power factor (per phase & average)

Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

Load histogram feature

Generator set packages include:

Frequency (Hz)

Emergency stop pushbutton

Over/under voltage (27/59)

RFI suppression

24 Volt DC operation

Low coolant level

Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

4 Programmable relay outputs (Form A)

Volts (L-L & L-N)

Caterpillar's voltage regulator

IVR includes:

Auto/start/stop control

kVA (per phase, average & percent)

Lamp test

Over/under frequency (81 o/u)

Environmental sealed front face

3 Phase voltage sensing

Engine cool

kVAr-hr (total)

Low oil pressure

Accessory module data link

Emergency stop

Customer data link (Modbus RTU)

Communications:

Warning/shutdown with common LED indication of shutdowns for:

0 True RMS AC metering, 3-phase, +/-2% accuracy

Digital indication for:

Customizable screens

Failure to start (overcrank)

Serial annunciator module data link

Coolant temperature

Controls:

Overcurrent (50/51)

Number of I/O varies on options selected

Reactive droop capability

Low coolant temperature

High coolant temperature

Min / max exciter

Alarm acknowledge

RPM

Generator phase sequence

Limiter and exciter diode monitor

Speed adjust

Operating hours

kW (per phase, average & percent)

3 Analog inputs

Generator mounted - rear facing

6 Customer programmable digital inputs

Lubrication System

Oil filter, filler and dipstick

Oil drain lines and valve

Gear type lube oil pump

Fumes disposal

Lubricating oil

Mounting System

Rubber anti-vibration mounts - shipped loose

Rails - engine/generator/radiator mounting

Anti-vibration mounts (shipped loose)

Starting System

45 Amp Charging alternator

24 Volt electric starting motor

Battery and battery rack w/cables

Battery disconnect switch

Literature

Parts book

Operation & Maintenance Manual

Optional Equipment

Control System

EMCP 4.3, EMCP 4.4

Air Inlet System

Dual element air cleaner

Single element filter

Cooling System

Water level switch gauges

Optional installed ATAAC radiators

Standard ambient ATAAC radiators

Standard ambient radiators

Coolant

Optional installed radiators

Crankcase System

Explosion relief valves

No explosion relief valves

Ventilation system

Exhaust System

Elbows

Flange and exhaust expanders

Tier 4 clean emissions module

Tier 4 clean emission MOD Kits

Clean emission parts

Exhaust offset

Mufflers

Tier 4 dosing cabinet

Flanges

Flexible fittings

Y Adapters

Fuel System

Fuel priming pumps (Tier 4) - Manual or electric

Primary fuel filter

General

US aid emblem

Special paint (Colors other than Caterpillar yellow or high performance paints)

Generators and Attachments

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Generator conversion

Differential current transformers (DCT)

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Thermostat for space heater

Space heater

High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

Alternator air cleaner

High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

Instrumentation

Pyrometer and Thermocouples

Lubrication System

Oil level regulator

Prelube pumps

Lube oil in standard sump

Mounting System

Puck style low efficiency isolators

Spring type vibration isolators

IBC vibration isolators

Power Connections

Right side power connections

Ground cables between generator and terminal box

Neutral ground connections

Low voltage Circuit breakers

2700 Frame, four lead, four terminal

Rear power connections

Left side power connections

Center post busbars

Special Tests / Reports

PGS Test report @ 0.8 power factor

PGS Test report @ 1.0 power factor

Fuel consumption test

Canadian Standards Association certification

Torsional vibration analysis reports

IBC Certification

Generator test report

Generator set fuel consumption test

OSHPD Certification

Standard engine test charge

Starting and Charging

Engine barring device

Air pressure regulator

Starter cover

Electric starting motors

Jacket water heaters

Air starting motors

24 Volt battery set - Dry

10, 20, 35 and 50 Amp Battery chargers

Extended Service Coverage

Platinum, Gold and Silver coverage

    Send an Enquiry