402

3516 Diesel Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Standby Rating

2000 kVA

Prime Power Rating

1825 kVA

Emissions/Fuel Strategy

Low Fuel Consumption

Voltage

380 to 11000 Volts

Frequency

50 Hz

Speed

1500 rpm

Duty Cycle

Standby, Mission Critical, Prime, Continuous

Maximum Rating

2000 kVA

Minimum Rating

1600 kVA

Engine Model

3516 TA, V-16, 4-Stroke Water-Cooled Diesel

Bore

6.69in

Stroke

7.48in

Displacement

4210.64in³

Compression Ratio

13.0:1

Aspiration

TA

Fuel System

Mechanical unit injection

Governor Type

Woodward

Length - Minimum

249.2in

Length - Maximum

249.2in

Width - Minimum

90in

Width - Maximum

90in

Height - Minimum

94.9in

Height - Maximum

94.9in

Dry Weight - Genset (minimum)

36750lb

Dry Weight - Genset (maximum)

36750lb

Air Inlet System

Dual element air cleaner

Single element filter

Exhaust

Exhaust mufflers

Cooling System

Optional installed radiators

Coolant

Standard ambient ATAAC radiators

Optional installed ATAAC radiators

Standard ambient radiators

Water level switch gauges

Generator

Internal excitation (IE)

Anti-condensation heater

Oversize and premium generators

Permanent magnet excitation (PMG)

Crankcase System

No explosion relief valves

Ventilation system

Explosion relief valves

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Control Panels

Remote monitoring software

Generator temperature monitoring & protection

Load share module

Digital I/O module

EMCP 4.2B

Exhaust System

Exhaust offset

Tier 4 dosing cabinet

Flexible fittings

Mufflers

Tier 4 clean emissions module

Elbows

Flange and exhaust expanders

Tier 4 clean emission MOD Kits

Flanges

Clean emission parts

Y Adapters

Mounting

Spring type vibration isolators

IBC isolators

Rubber anti-vibration mounts

Fuel System

Fuel priming pumps (Tier 4) - Manual or electric

Primary fuel filter

Starting/Charging

Jacket water heater

Oversize batteries

Battery chargers

Air starting motor with control and silencer

Heavy duty starting system

Charging alternator

General

Special paint (Colors other than Caterpillar yellow or high performance paints)

US aid emblem

Generators and Attachments

Thermostat for space heater

Alternator air cleaner

Differential current transformers (DCT)

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Generator conversion

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Space heater

Instrumentation

Pyrometer and thermocouples

Lubrication System

Oil level regulator

Prelube pumps

Lube oil in standard sump

Mounting System

Spring type vibration isolators

Puck style low efficiency isolators

IBC vibration isolators

Power Connections

Neutral ground connections

Center post busbars

Right side power connections

Rear power connections

2700 Frame, four lead, four terminal

Left side power connections

Ground cables between generator and terminal box

Low voltage Circuit breakers

Special Tests / Reports

IBC Certification

Standard engine test charge

PGS Test report @ 1.0 power factor

Generator test report

Fuel consumption test

Canadian Standards Association certification

PGS Test report @ 0.8 power factor

OSHPD Certification

Torsional vibration analysis reports

Generator set fuel consumption test

Starting and Charging

Electric starting motors

Air pressure regulator

24 Volt battery set - Dry

Engine barring device

Starter cover

Air starting motors

Jacket water heaters

10, 20, 35 and 50 Amp Battery chargers

Extended Service Coverage

Platinum, Gold and Silver coverage

Air Inlet System

Air cleaner; single element canister type

Air Inlet

Air cleaner

Cooling

Package mounted radiator

Exhaust

Exhaust flange outlet

Fuel

Secondary fuel filters

Fuel priming pump

Primary fuel filter with integral water separator

Generator

Matched to the performance and output characteristics of Cat engines

IP23 Protection

Power Termination

Busbar

Control Panel

EMCP 4 Genset controller

Control Panels

Over/under voltage (27/59)

Serial annunciator module data link

Communications:

Overcurrent (50/51)

Over/under frequency (81 o/u

Text alarm/event descriptions

Generator set packages include Caterpillar's voltage regulator

Programmable protective relaying functions:

4 Programmable relay outputs (Form A)

Reverse power (kW) (32)

Emergency stop

Amps (per phase & average)

Oil pressure (psi, kPa or bar)

Operating hours

24 Volt DC operation

Low oil pressure

6 Customer programmable digital inputs

1 Programmable digital outputs

1 Programmable relay outputs (Form C)

Volts (L-L & L-N)

Number of I/O varies on options selected

RPM - DC volts

Low coolant level

kVAr-hr (total)

Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

kW-hr (total)

Failure to start (overcrank)

Environmental sealed front face

Power factor (per phase & average)

Accessory module data link

Generator mounted - rear facing

High coolant temperature

Overspeed

3 Analog inputs

Frequency (Hz)

Warning/shutdown with common LED indication of shutdowns for

Coolant temperature

IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor

Customer data link (Modbus RTU)

kVA (per phase, average & percent)

Cat connect

Generator phase sequence

Reverse reactive power (kVAr) (32RV

DC volts

kW (per phase, average & percent)

kVAr (per phase, average & percent)

Emergency stop pushbutton

Digital indication for:

Low coolant temperature

EMCP 4.2B

Cooling System

Certified standard PGS provided

Exhaust System

Flanged faced outlet(s)

Dry exhaust manifold

Fuel System

Flexible fuel lines - shipped loose

Fuel priming pump

Fuel cooler; not included with packages without radiator

Secondary fuel filters

General

SAE standard rotation

Flywheel and flywheel housing - SAE No. 00

Right hand servicing

Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

Medium voltage:

Form wound

Winding temperature detectors

High voltage:

3 Phase brushless, Salient pole

Permanent magnet excitation (PMG)

Permanent magnet excitation (PMG)

NEMA standard hole pattern

Internal excitation (IE)

Six lead

Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

Low voltage:

Winding temperature detectors

NEMA standard hole pattern

Form wound

Winding temperature detectors

Random wound

Busbar connections, top center mounted, top cable entry

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Anti-condensation space heater

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Governing System

ADEM A3

Literature

Parts book

Lubrication System

Gear type lube oil pump

Fumes disposal

Oil drain lines and valve

Lubricating oil

Oil filter, filler and dipstick

Integral lube oil cool

Mounting System

Anti-vibration mounts (shipped loose)

Rubber anti-vibration mounts - shipped loose

Rails - Engine/generator/radiator mounting

Starting System

Battery disconnect switch

Battery and battery rack w/cables

45 Amp Charging alternator

24 Volt electric starting motor

ALL

Air Inlet System

Air cleaner; single element canister type

Air Inlet

Air cleaner

Cooling

Package mounted radiator

Exhaust

Exhaust flange outlet

Fuel

Secondary fuel filters

Fuel priming pump

Primary fuel filter with integral water separator

Generator

Matched to the performance and output characteristics of Cat engines

IP23 Protection

Power Termination

Busbar

Control Panel

EMCP 4 Genset controller

Control Panels

Over/under voltage (27/59)

Serial annunciator module data link

Communications:

Overcurrent (50/51)

Over/under frequency (81 o/u

Text alarm/event descriptions

Generator set packages include Caterpillar's voltage regulator

Programmable protective relaying functions:

4 Programmable relay outputs (Form A)

Reverse power (kW) (32)

Emergency stop

Amps (per phase & average)

Oil pressure (psi, kPa or bar)

Operating hours

24 Volt DC operation

Low oil pressure

6 Customer programmable digital inputs

1 Programmable digital outputs

1 Programmable relay outputs (Form C)

Volts (L-L & L-N)

Number of I/O varies on options selected

RPM - DC volts

Low coolant level

kVAr-hr (total)

Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

kW-hr (total)

Failure to start (overcrank)

Environmental sealed front face

Power factor (per phase & average)

Accessory module data link

Generator mounted - rear facing

High coolant temperature

Overspeed

3 Analog inputs

Frequency (Hz)

Warning/shutdown with common LED indication of shutdowns for

Coolant temperature

IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor

Customer data link (Modbus RTU)

kVA (per phase, average & percent)

Cat connect

Generator phase sequence

Reverse reactive power (kVAr) (32RV

DC volts

kW (per phase, average & percent)

kVAr (per phase, average & percent)

Emergency stop pushbutton

Digital indication for:

Low coolant temperature

EMCP 4.2B

Cooling System

Certified standard PGS provided

Exhaust System

Flanged faced outlet(s)

Dry exhaust manifold

Fuel System

Flexible fuel lines - shipped loose

Fuel priming pump

Fuel cooler; not included with packages without radiator

Secondary fuel filters

General

SAE standard rotation

Flywheel and flywheel housing - SAE No. 00

Right hand servicing

Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

Medium voltage:

Form wound

Winding temperature detectors

High voltage:

3 Phase brushless, Salient pole

Permanent magnet excitation (PMG)

Permanent magnet excitation (PMG)

NEMA standard hole pattern

Internal excitation (IE)

Six lead

Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

Low voltage:

Winding temperature detectors

NEMA standard hole pattern

Form wound

Winding temperature detectors

Random wound

Busbar connections, top center mounted, top cable entry

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Anti-condensation space heater

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Governing System

ADEM A3

Literature

Parts book

Lubrication System

Gear type lube oil pump

Fumes disposal

Oil drain lines and valve

Lubricating oil

Oil filter, filler and dipstick

Integral lube oil cool

Mounting System

Anti-vibration mounts (shipped loose)

Rubber anti-vibration mounts - shipped loose

Rails - Engine/generator/radiator mounting

Starting System

Battery disconnect switch

Battery and battery rack w/cables

45 Amp Charging alternator

24 Volt electric starting motor

Optional Equipment

Air Inlet System

Dual element air cleaner

Single element filter

Exhaust

Exhaust mufflers <!--(except Tier 4)-->

Cooling System

Optional installed radiators

Coolant

Standard ambient ATAAC radiators

Optional installed ATAAC radiators

Standard ambient radiators

Water level switch gauges

Generator

Internal excitation (IE)

Anti-condensation heater

Oversize and premium generators

Permanent magnet excitation (PMG)

Crankcase System

No explosion relief valves

Ventilation system

Explosion relief valves

Power Termination

Circuit breakers, UL listed

Circuit breakers, IEC compliant

Control Panels

Remote monitoring software

Generator temperature monitoring & protection

Load share module

Digital I/O module

EMCP 4.2B

Exhaust System

Exhaust offset

Tier 4 dosing cabinet

Flexible fittings

Mufflers

Tier 4 clean emissions module

Elbows

Flange and exhaust expanders

Tier 4 clean emission MOD Kits

Flanges

Clean emission parts

Y Adapters

Mounting

Spring type vibration isolators

IBC isolators

Rubber anti-vibration mounts

Fuel System

Fuel priming pumps (Tier 4) - Manual or electric

Primary fuel filter

Starting/Charging

Jacket water heater

Oversize batteries

Battery chargers

Air starting motor with control and silencer

Heavy duty starting system

Charging alternator

General

Special paint (Colors other than Caterpillar yellow or high performance paints)

US aid emblem

Generators and Attachments

Thermostat for space heater

Alternator air cleaner

Differential current transformers (DCT)

Differential current transformers (DCT) 8.7 kV and 15 kV classes

Generator conversion

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Space heater

Instrumentation

Pyrometer and thermocouples

Lubrication System

Oil level regulator

Prelube pumps

Lube oil in standard sump

Mounting System

Spring type vibration isolators

Puck style low efficiency isolators

IBC vibration isolators

Power Connections

Neutral ground connections

Center post busbars

Right side power connections

Rear power connections

2700 Frame, four lead, four terminal

Left side power connections

Ground cables between generator and terminal box

Low voltage Circuit breakers

Special Tests / Reports

IBC Certification

Standard engine test charge

PGS Test report @ 1.0 power factor

Generator test report

Fuel consumption test

Canadian Standards Association certification

PGS Test report @ 0.8 power factor

OSHPD Certification

Torsional vibration analysis reports

Generator set fuel consumption test

Starting and Charging

Electric starting motors

Air pressure regulator

24 Volt battery set - Dry

Engine barring device

Starter cover

Air starting motors

Jacket water heaters

10, 20, 35 and 50 Amp Battery chargers

Extended Service Coverage

Platinum, Gold and Silver coverage

    Send an Enquiry