402

DG200-2 (3 phase)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

  • Specifications

  • Standard/Optional Equipment

  • Catalog

Frequency

60 Hz

Natural Gas Rating

200 eKW

Emissions/Fuel Strategy

U.S. EPA Certified for Non-Emergency Application

Engine Model

14.2 L, Inline 6, 4 Cycle, Spark - Ignited

Displacement

864.71in

Fuel System

Carburetor, Down Draft

Fuel Type

Natural Gas

Speed

1800 rpm

Aspiration

Turbocharged-Aftercooled

Governor Type

Electronic

Compression Ratio

9.5:1

Bore

5.31in

Stroke

6.5in

Length

127.95in

Width

52.93in

Height

67.37in

Weight

5756lb

Starting/Charging

Jacket water heater

Battery heater

Charging alternator

Battery charger – UL Listed 10 amp

General

Enclosures: sound attenuated, weather protective

Suitable for Use as Service Equipment (SUSE)

Automatic transfer switches (ATS)

UL 2200 package

CSA Certification

Generator

Thermal magnetic or electronic trip MCCBs

Anti-condensation heater

Shunt trip and auxiliary contact breaker

Anti-condensation heater

Excitation: [ ] Permanent Magnet Excited (PM)

Oversize and premium generators

Cooling

Closed coolant recovery system

Factory-installed radiator

50/50 Ethylene glycol antifreeze

Radiator and cooling fan complete with protective guards

Standard ambient temperatures up to 50°C (122°F)

Air Inlet

Single element air filter

Fuel

Primary and secondary fuel shut-off

Low fuel pressure switch

Fuel pressure test po

Natural Gas or LP Vapor

NPT connection

Dual lock off valves

Exhaust

Exhaust outlet with 3” pipe

Generator

Permanent magnet excitation

Full load capacity alternator

Class H insulation material

Permanent magnet excitation

Integrated Voltage Regulator

Matched to the performance and output characteristics of Cat engines

Class H insulation material

Full load capacity alternator

IP23 Protection

Controls

EMCP 4.2 Series generator set controller

Mounting

Vibration isolaton (puck type)

Rubber vibration isolators

Electric Power - Package Serial Number Prefix

Battery charging alternator

Electric Starting and/or Prelube

Battery cables

Solenoid activated starter motor

Engine electrical system

Solenoid activated starter motor

Governor

Electronic governor (non adjustable)

Control Panel

EMCP 4.2 Series generator set controller

Starting/Charging

Batteries with rack and cables

12 volt starting motor

ALL

Cooling

Closed coolant recovery system

Factory-installed radiator

50/50 Ethylene glycol antifreeze

Radiator and cooling fan complete with protective guards

Standard ambient temperatures up to 50°C (122°F)

Air Inlet

Single element air filter

Fuel

Primary and secondary fuel shut-off

Low fuel pressure switch

Fuel pressure test po

Natural Gas or LP Vapor

NPT connection

Dual lock off valves

Exhaust

Exhaust outlet with 3” pipe

Generator

Permanent magnet excitation

Full load capacity alternator

Class H insulation material

Permanent magnet excitation

Integrated Voltage Regulator

Matched to the performance and output characteristics of Cat engines

Class H insulation material

Full load capacity alternator

IP23 Protection

Controls

EMCP 4.2 Series generator set controller

Mounting

Vibration isolaton (puck type)

Rubber vibration isolators

Electric Power - Package Serial Number Prefix

Battery charging alternator

Electric Starting and/or Prelube

Battery cables

Solenoid activated starter motor

Engine electrical system

Solenoid activated starter motor

Governor

Electronic governor (non adjustable)

Control Panel

EMCP 4.2 Series generator set controller

Starting/Charging

Batteries with rack and cables

12 volt starting motor

Optional Equipment

Starting/Charging

Jacket water heater

Battery heater

Charging alternator

Battery charger – UL Listed 10 amp

General

Enclosures: sound attenuated, weather protective

Suitable for Use as Service Equipment (SUSE)

Automatic transfer switches (ATS)

UL 2200 package

CSA Certification

Generator

Thermal magnetic or electronic trip MCCBs

Anti-condensation heater

Shunt trip and auxiliary contact breaker

Anti-condensation heater

Excitation: [ ] Permanent Magnet Excited (PM)

Oversize and premium generators

    Send an Enquiry